Printing
4.
Select the printout type from the
Printout
list.
Note that the printing location (see step 5) for
Telemetry Waveforms
will only be
sent to the telemetry when starting the combination monitoring mode with a
non-admitted telemetry patient.
5.
Select the location for the printout:
If you are printing to this location
Select this option
Local recorder XE-50 or PRN 50-M
(connected directly to or built in the
monitor).
This selection is only available for
Telemetry Waveforms
if the PRN 50-M
recorder is connected.
Local
Remote recorder or printer (a recorder
in another monitor in the CARESCAPE
network, or a recorder or a printer
connected to a central station in the
network).
Remote
Network printer (a printer in the IX Network
or connected to an iCentral).
This is always the print location for reports.
This is not available if the printout type is
Telemetry Waveforms
.
Network
6.
According to your location selection above:
a. If you selected
Network
: Select the print device from the
Network Device
list.
b. If you selected
Remote
: Choose the monitor or central station from the
Unit
list, and then select the print device from the
Remote Device
list.
NOTE
You may assign one printout type to one print location only.
NOTE
Changing the print location does not affect printing currently
in progress.
Checking the print status
You can view the assigned print locations for each type of printout and check the
printer status for each print device.
1.
Select
Monitor Setup
>
Printing
.
2.
Select the
Devices
tab >
Status
.
Printing waveforms
Printing waveforms for an arrhythmia alarm
NOTE
Automatic printing of waveforms is always initiated by an
alarm.
1.
Select
Alarm Setup
from the main menu.
436
CARESCAPE Modular Monitors
2062971-001
Summary of Contents for CARESCAPE
Page 38: ...38 CARESCAPE Modular Monitors 2062971 001 ...
Page 114: ...Setting up the monitor before use 114 CARESCAPE Modular Monitors 2062971 001 ...
Page 146: ...Alarms 146 CARESCAPE Modular Monitors 2062971 001 ...
Page 218: ...Pulse oximetry 218 CARESCAPE Modular Monitors 2062971 001 ...
Page 234: ...Non invasive blood pressure 234 CARESCAPE Modular Monitors 2062971 001 ...
Page 260: ...Temperature 260 CARESCAPE Modular Monitors 2062971 001 ...
Page 274: ...Cardiac output 274 CARESCAPE Modular Monitors 2062971 001 ...
Page 280: ...Mixed venous oxygen saturation SvO 280 CARESCAPE Modular Monitors 2062971 001 ...
Page 338: ...Patient Spirometry 338 CARESCAPE Modular Monitors 2062971 001 ...
Page 372: ...Neuromuscular transmission 372 CARESCAPE Modular Monitors 2062971 001 ...
Page 404: ...Laboratory data 404 CARESCAPE Modular Monitors 2062971 001 ...
Page 410: ...Calculations 410 CARESCAPE Modular Monitors 2062971 001 ...
Page 416: ...Drug calculations 416 CARESCAPE Modular Monitors 2062971 001 ...
Page 424: ...Trends 424 CARESCAPE Modular Monitors 2062971 001 ...
Page 432: ...Snapshots and events 432 CARESCAPE Modular Monitors 2062971 001 ...
Page 462: ...Cleaning and care 462 CARESCAPE Modular Monitors 2062971 001 ...
Page 528: ...Abbreviations yr year yrs years 528 CARESCAPE Modular Monitors 2062971 001 ...
Page 546: ...Skills checklist 546 CARESCAPE Modular Monitors 2062971 001 ...
Page 547: ...content ...