ECG
4.
Enter the
Technician ID
if required.
5.
Enter the
Order Number
.
6.
Select an option from the
Reasons for 12 Lead
list.
You can also add your own password protected list of pre-defined reasons for
recording a 12 lead ECG through the
Care Unit Settings
.
7.
Select
Cancel
or
Confirm
.
Entering data for an ACI-TIPI 12 lead ECG analysis
NOTE
The patient must be at least 16 years old for an ACI-TIPI 12
lead ECG analysis.
1.
Select the HR parameter window.
2.
Select
12 Lead Analysis
.
3.
Select
Settings
.
4.
Select
On
from the
ACI - TIPI
list.
5.
Select the patient’s gender from the
Gender
list.
This selection will also be updated to the patient demographics.
6.
If the patient’s age has not been entered previously, select it now from the
Age
list.
7.
Select the symptoms present from the
Chest or Left Arm Pain
list.
8.
Select
Cancel
or
Confirm
.
Selecting
Confirm
is required before you can complete an ACI-TIPI 12 lead ECG
analysis.
Enabling and disabling the 12SL ACS
WARNING
Acute Coronary Syndrome (ACS) feature must be used only
with patients to whom this measurement is suitable.
12SL-ACS is an optional higher-sensitivity analysis for the detection of acute ischemia
and acute infarction designed for a higher risk population with a higher prior
probability of having these conditions. When this setting is enabled, you will get
ACS-specific statements in addition to the diagnostic statements.
1.
Select the HR parameter window.
2.
Select
12 Lead Analysis
.
3.
Select
Settings
.
4.
Select
On
or
Off
from the
ACS
list.
5.
Select
Cancel
or
Confirm
.
Entering the
Location ID
for 12SL
If roving between units is allowed and the 12SL ECG with ACI TIPI is enabled, you can
enter the
Location ID
that will be used in the 12SL reports.
1.
Select the patient information area on screen.
2.
Select the
Care Unit & Bed
tab.
168
CARESCAPE Modular Monitors
2062971-001
Summary of Contents for CARESCAPE
Page 38: ...38 CARESCAPE Modular Monitors 2062971 001 ...
Page 114: ...Setting up the monitor before use 114 CARESCAPE Modular Monitors 2062971 001 ...
Page 146: ...Alarms 146 CARESCAPE Modular Monitors 2062971 001 ...
Page 218: ...Pulse oximetry 218 CARESCAPE Modular Monitors 2062971 001 ...
Page 234: ...Non invasive blood pressure 234 CARESCAPE Modular Monitors 2062971 001 ...
Page 260: ...Temperature 260 CARESCAPE Modular Monitors 2062971 001 ...
Page 274: ...Cardiac output 274 CARESCAPE Modular Monitors 2062971 001 ...
Page 280: ...Mixed venous oxygen saturation SvO 280 CARESCAPE Modular Monitors 2062971 001 ...
Page 338: ...Patient Spirometry 338 CARESCAPE Modular Monitors 2062971 001 ...
Page 372: ...Neuromuscular transmission 372 CARESCAPE Modular Monitors 2062971 001 ...
Page 404: ...Laboratory data 404 CARESCAPE Modular Monitors 2062971 001 ...
Page 410: ...Calculations 410 CARESCAPE Modular Monitors 2062971 001 ...
Page 416: ...Drug calculations 416 CARESCAPE Modular Monitors 2062971 001 ...
Page 424: ...Trends 424 CARESCAPE Modular Monitors 2062971 001 ...
Page 432: ...Snapshots and events 432 CARESCAPE Modular Monitors 2062971 001 ...
Page 462: ...Cleaning and care 462 CARESCAPE Modular Monitors 2062971 001 ...
Page 528: ...Abbreviations yr year yrs years 528 CARESCAPE Modular Monitors 2062971 001 ...
Page 546: ...Skills checklist 546 CARESCAPE Modular Monitors 2062971 001 ...
Page 547: ...content ...