Trends
Changing the graphic trend scales
1.
Select
Trends
.
2.
Select
Graphic
from the
View
list.
3.
Select
Trend Scales
.
4.
Select the
General
,
IP/NIBP
,
Cardiac Output
, or
Temp
tab.
5.
Set the trend scales for required parameters.
Printing currently viewed graphic trends
1.
Select
Trends
.
2.
Select
Graphic
from the
View
list.
3.
Select
Print Page
.
4.
You can stop printing by selecting
Cancel Printing
.
Printing all graphic trend data
1.
Select
Monitor Setup
>
Printing
.
2.
Select
Reports
>
Trends
.
3.
Select
.
4.
You can stop printing by selecting
Cancel Printing
.
Graphic trend resolution and the high-resolution license
The graphic trend resolution depends on the time scale of the trend. Graphic trends
are updated once a minute when the time scale is 1 hour or more. For the 20 minute
scale, the update rate is 10 seconds.
High-resolution trends is a licensed graphic trend option that provides an increased
resolution of 2 seconds for the 2, 4, and 20 minute scales. The high resolution graphic
trend is updated on user request. This trend also contains compressed CO
2
and
impedance respiration waveforms (10 Hz) as well as beat-to-beat ECG heart rate
and mean arterial pressure MAP (6 Hz).
High-resolution trend data is not saved over power down situations. This means that
data in the 2, 4, and 20 minute time scales is erased.
High-resolution trend data is neither sent nor loaded to/from the network (central
station) or acquisition modules (PDM, TRAM).
Numeric trends
Viewing numeric trends
Numeric trends contain nine pages with 24 or 72 hours of trend data depending on
the trend license. The top of the view shows the highest priority realtime waveform.
The lowest row,
Mark
, shows snapshot event numbers. If more than one snapshot has
been created in a one-minute period, only the last snapshot event number is shown.
You cannot configure the layout of the
Numeric
trend view.
1.
Select
Trends
.
2062971-001
CARESCAPE Modular Monitors
419
Summary of Contents for CARESCAPE
Page 38: ...38 CARESCAPE Modular Monitors 2062971 001 ...
Page 114: ...Setting up the monitor before use 114 CARESCAPE Modular Monitors 2062971 001 ...
Page 146: ...Alarms 146 CARESCAPE Modular Monitors 2062971 001 ...
Page 218: ...Pulse oximetry 218 CARESCAPE Modular Monitors 2062971 001 ...
Page 234: ...Non invasive blood pressure 234 CARESCAPE Modular Monitors 2062971 001 ...
Page 260: ...Temperature 260 CARESCAPE Modular Monitors 2062971 001 ...
Page 274: ...Cardiac output 274 CARESCAPE Modular Monitors 2062971 001 ...
Page 280: ...Mixed venous oxygen saturation SvO 280 CARESCAPE Modular Monitors 2062971 001 ...
Page 338: ...Patient Spirometry 338 CARESCAPE Modular Monitors 2062971 001 ...
Page 372: ...Neuromuscular transmission 372 CARESCAPE Modular Monitors 2062971 001 ...
Page 404: ...Laboratory data 404 CARESCAPE Modular Monitors 2062971 001 ...
Page 410: ...Calculations 410 CARESCAPE Modular Monitors 2062971 001 ...
Page 416: ...Drug calculations 416 CARESCAPE Modular Monitors 2062971 001 ...
Page 424: ...Trends 424 CARESCAPE Modular Monitors 2062971 001 ...
Page 432: ...Snapshots and events 432 CARESCAPE Modular Monitors 2062971 001 ...
Page 462: ...Cleaning and care 462 CARESCAPE Modular Monitors 2062971 001 ...
Page 528: ...Abbreviations yr year yrs years 528 CARESCAPE Modular Monitors 2062971 001 ...
Page 546: ...Skills checklist 546 CARESCAPE Modular Monitors 2062971 001 ...
Page 547: ...content ...