Table D-29 lists error codes and descriptions used in registers
test error messages.
Table D-29. Registers Test Error Codes and Descriptions
Error Code and Description
Meaning
(1: CSR[
n
]=
x
- xpctd 0 )
Write and read operation to
Ethernet CSR[
n
] failed. The
n
represents the number of the CSR
involved in the failure.
(3: CSR[1]=
xxxx
- xpctd 0xFFFE)
Writing and reading 0xFFFE failed
on CSR 1.
xxxx
represents the
actual value in CSR 1.
(4: CSR[2]=
xxxx
- xpctd 00FF)
Writing and reading 0x00FF failed
on CSR 2.
xxxx
represents the
actual value in CSR 2.
(5: CSR[1]=
xxxx
- bit lk frm CSR[2])
Bit leak from CSR2 to CSR1
occurred.
xxxx
represents the actual
value in CSR[1].
(6: CSR[2]=
xxxx
- bit lk frm CSR[1])
Bit leak from CSR1 to CSR2
occurred.
xxxx
represents the actual
value in CSR[2].
(7: immediate write/read
flr)
Immediate write and read failure
occurred.
Base System Test Commands and Messages