Table A-15 (Cont.). VRT16-DA and VRT16-D4 Monitor Description
– Sync pulse
1,335.1 ns
Vertical rate timing
– Active video
14.4915 ms
– Blanking interval
39 horizontal lines
– Frequency
66.4743 Hz
– Front porch
3 horizontal lines
– Sync pulse
3 horizontal lines
– Vertical period
15.0434 ms
Video rate
– Pixel frequency
119.843 MHz
– Pixel period
8.3443 ns nominal
Power
– ac input voltage
90–132 or 198–264 Vac
Switch selectable
– Frequency
47 to 63 Hz
– Power consumption
200 watts maximum
Table A-16. VRT16-DA and VRT16-D4 Monitor Operating Conditions
Temperature range
1
10°C to 35°C (50° to 95°F)
Relative humidity
10% to 95%
Maximum wet-bulb temperature
32°C ( 89°F)
Minimum dew-point temperature
2°C (36°F)
Altitude
10,000 ft maximum
1
Reduce maximum temperature by 1.8°C for each 1,000 meter (1.0°F for each 1,000 ft) increase in
altitude.
Table A-17. VRT16-DA and VRT16-D4 Monitor Nonoperating Conditions
Temperature range
40°C to 60°C ( 40°F to 145°F)
Relative humidity
10% to 95%
Maximum wet-bulb temperature
46°C (115°F) packaged
Altitude
12,780 m (50,000 ft) maximum
Equipment Specifications
A–15
Summary of Contents for DECstation 5000/100 Series
Page 20: ......
Page 24: ......
Page 36: ......
Page 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Page 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Page 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Page 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Page 164: ......
Page 206: ......
Page 356: ......
Page 388: ......