Table D-31. SCSI Send Diagnostics Test Error Descriptions
Error Description
Meaning
(1: dev ol)
Test could not bring the unit on line.
(2: dev ol)
Test could not bring the unit on line.
(3: sdiag)
Device failed the send diagnostics test.
SCSI Target Test
The SCSI target test performs a read test on a specific SCSI
device. If you include the optional write parameter, the test
also performs a write test. To run the SCSI target test, type
t 3/target
scsi_id
[
w
] [
l
loops
] and press Return.
When you type the SCSI target test command,
Replace the
scsi_id
parameter with the SCSI ID of the
device you want to test.
Specify the optional w parameter to include a write
operation in the SCSI target test.
Specify the optional l parameter to have the test repeat up
to 9 times. If you include the l parameter, replace
loops
with the number of times you want the test to repeat.
Caution:
This test can ruin existing data if run with the w option.
The test writes over existing data at random.
SCSI target test error messages
SCSI target test error messages have the form
?TFL: 3/scsi/target (
code
:
description
)
?TFL 3/scsi/target indicates that the SCSI target test
reported an error.
code
represents a number that indicates which portion of
the test failed.
description
represents additional information that describes
the failure.
D–60
Base System Test Commands and Messages
Summary of Contents for DECstation 5000/100 Series
Page 20: ......
Page 24: ......
Page 36: ......
Page 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Page 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Page 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Page 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Page 164: ......
Page 206: ......
Page 356: ......
Page 388: ......