Table D-9 lists the error codes and descriptions used in SCC
transmit and receive error messages.
Table D-9. SCC Transmit and Receive Test Error Codes and Descriptions
Error Code and
Description
Meaning
1: Ln
N
tx bfr
not empty.
status=
xx
System could not write a single character because the
transmit buffer was not empty.
N
represents the line in
which the error occurred. The status value is the contents
of SCC read register 0.
2: Ln
N
char
not rcvd.
status=
xx
CHAR AVAIL signal not received when the system was
expecting a character.
N
represents the line in which the
error occurred. The status value is the contents of SCC
read register 0.
3: Ln
N
expctd=
xx
,
rcvd=
yy
,
status=
zz
The character that was received was different than the
transmitted character.
N
represents the line in which the
error occurred. The
xx
represents the transmitted value.
The
yy
represents the received value. The status value is
the contents of SCC read register 0.
4: Ln
N
Rx err.
errs=
xx
Receiving character in FIFO reported an error.
N
represents the line in which the error occurred. The errs
value is the associated input character FIFO error bits.
Base System Test Commands and Messages
D–21
Summary of Contents for DECstation 5000/100 Series
Page 20: ......
Page 24: ......
Page 36: ......
Page 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Page 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Page 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Page 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Page 164: ......
Page 206: ......
Page 356: ......
Page 388: ......