Base System Ethernet Controller Tests
The following entries explain the commands, parameters, and
error messages for each individual Ethernet controller test.
Collision Test
The collision test checks Ethernet collision detect circuitry by
forcing a collision on transmission. To run the collision test,
type
t 3/ni/cllsn
and press Return.
Collision test error messages
Collision test error messages have the form
?TFL: 3/ni/cllsn (
code
:
description
)
?TFL: 3/ni/cllsn indicates that the collision test reported a
problem.
code
represents a number that identifies which portion of
the test failed.
description
represents additional information that describes
the failure.
Table D-18 lists error codes and descriptions used in collision
test error messages.
Table D-18. Collision Test Error Codes and Descriptions
Error Code and Description
Meaning
(3: cllsn not dtctd)
Ethernet controller chip failed to detect an
Ethernet collision.
(4: xmt [
x
])
Ethernet controller chip transmission failed.
(6: LANCE-init [
x
])
Ethernet controller chip failed to initialize.
D–40
Base System Test Commands and Messages
Summary of Contents for DECstation 5000/100 Series
Page 20: ......
Page 24: ......
Page 36: ......
Page 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Page 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Page 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Page 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Page 164: ......
Page 206: ......
Page 356: ......
Page 388: ......