Table 4-2. Interpreting Base System Test Error Messages Displayed on the Monitor
Test Listed in the
Error Message
Component Tested
Corrective Action
cache/data
cache/fill
cache/isol
cache/reload
cache/seg
fpu
CPU module
Replace the CPU module. Refer to
‘‘Removing and Replacing a CPU
Module’’ in Chapter 5 for directions.
If the problem persists, replace the
system module. Refer to ‘‘Removing
and Replacing a System Module’’ in
Chapter 5 for directions.
mem
mem/float10
Memory modules
Refer to ‘‘Troubleshooting the Memory
Modules’’ later in this chapter to
troubleshoot.
mem/select
Memory and system
module
Replace the memory module that
the mem/select test reports is bad.
If the problem persists, replace the
system module. Refer to ‘‘Removing
and Replacing a Memory Module’’ and
‘‘Removing and Replacing a System
Module’’ in Chapter 5 for directions.
misc/halt
System module
Replace the system module. Refer to
‘‘Removing and Replacing a System
Module’’ in Chapter 5 for directions.
misc/kbd
Keyboard and system
module
Refer to ‘‘Troubleshooting the Keyboard
and Mouse’’ later in this chapter to
troubleshoot.
misc/mouse
Mouse and system module
Refer to ‘‘Troubleshooting the Keyboard
and Mouse’’ later in this chapter to
troubleshoot.
misc/pstemp
Power supply
Refer to ‘‘Troubleshooting the Power
Supply’’ later in this chapter to
troubleshoot.
(continued on next page)
4–16
Identifying Failed FRUs
Summary of Contents for DECstation 5000/100 Series
Page 20: ......
Page 24: ......
Page 36: ......
Page 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Page 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Page 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Page 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Page 164: ......
Page 206: ......
Page 356: ......
Page 388: ......