Compare error messages, which have the form ?TFL:3/mem
@
address
=
actual
,
expected
?TFL 3/mem @ indicates that the memory test reported
a compare error.
The
address
parameter is the address at which the
error occurred.
actual
represents the value at that address.
expected
represents the expected value at that address.
Zero Memory Utility
The zero memory utility floods memory with zeros as fast as
possible. To run the zero memory test, type
t 3/mem/init
and
press Return.
The zero memory utility returns no error codes.
RAM Select Lines Test
The RAM select lines test checks for RAM select line faults
by performing a read and write operation on one location in
each memory module. To run the RAM select lines test, type
t
3/mem/select
and press Return.
RAM select lines test error messages
The only RAM select test error message is
?TFL: 3/mem/select (
address
=
actual
, sb
expected
)
?TFL: 3/mem/select indicates that the RAM select lines test
reported an error.
address
represents the memory address where the error
occurred.
actual
represents the actual value at the listed address.
expected
represents what the correct value at the listed
address should be.
D–38
Base System Test Commands and Messages
Summary of Contents for DECstation 5000/100 Series
Page 20: ......
Page 24: ......
Page 36: ......
Page 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Page 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Page 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Page 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Page 164: ......
Page 206: ......
Page 356: ......
Page 388: ......