Registers Test
The registers test performs a read and write operation on the
Ethernet registers. To run the registers test, type
t 3/ni/regs
and press Return.
Registers test error messages
Registers test error messages have the form
?TFL: 3/ni/regs (
code
:
description
)
?TFL: 3/ni/regs indicates that the registers test reported a
problem.
code
represents some number that identifies which portion
of the test failed.
description
represents additional information that describes
the failure.
The CSR[
n
] parameter, where
n
represents the number
of a specific CSR register, indicates the actual value in
the CSR register.
The xpctd parameter indicates the expected value for
the same CSR register.