To Interpret Memory Test Error Messages
The numbers following the word
bank
in the memory test error
message indicate which memory module reported the error.
The first number after the word
bank
is the slot number of
the problem module.
The code after the slot number indicates which memory
module in the slot reported the error.
If the code after the slot number is D16-31, the problem
module is the one farthest from the power supply.
If the code after the slot number is D0-15, the problem
module is the one nearest to the power supply.
Example: Memory test error message
The listing below is a sample
of a typical memory test error message:
?TFL:3/mem(PER, cause=0000001C, DBE=0040000c,
Bank 2, D16-31, d23-d16)
In this sample message, the problem module is in memory
slot 2. The code D16-31 indicates that the failed module is the
one farthest from the power supply.
4–26
Identifying Failed FRUs