Table D-15 lists error codes used in FPU test error messages.
Table D-15. FPU Test Error Codes
Error Code
Meaning
1
Values did not match. Value should be 00000000.
2
Values did not match. Value should be 55555555.
3
Values did not match. Value should be AAAAAAAA.
4
Values did not match. Value should be FFFFFFFF.
5
Least-significant bit failed when the system was converting
doubleword to word (CVT D. W.)
6
Most-significant bit failed when the system was converting
doubleword to word (CVT D. W.)
7
Double miscompare occurred: n+n-n!=n
8
Double miscompare occurred: n+n= =n
9
Convert float-double. Value should be 55555555.
10
FPU CSR double error occurred.
11
Single miscompare occurred. n+n-n!=n
12
Single miscompare occurred. n+n= =n
13
Convert float-double. Value should be 55555555.
14
FPU CSR single error occurred. Value should be 00000000.
15
Single division failed. Value should be 00005555.
16
Single multiplication failed.
17
Double multiplication failed.
18
Double division failed.
19
Conversion error occurred. Pattern readback did not match.
21
FPU did not trap on overflow exception.
Base System Test Commands and Messages
D–33
Summary of Contents for DECstation 5000/100 Series
Page 20: ......
Page 24: ......
Page 36: ......
Page 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Page 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Page 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Page 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Page 164: ......
Page 206: ......
Page 356: ......
Page 388: ......