background image

Summary of Contents for 3196

Page 1: ... _ IBM 3196 Display Station Setup Instructions GA18 2488 2 Part Number 81 X5374 i ...

Page 2: ......

Page 3: ...IBM 3196 Display Station Setup Instructions GA18 2488 2 Part Number 81 X5374 File Number S5250 36 38 06 ...

Page 4: ... for the outlet and plug wiring If it becomes necessary to change power cord or plug or if the outlet is improperly wired have the change made by a qualified electrician according to local or national code A new power cord may be ordered from your IBM sales representative Third Edition April 1987 This major revision obsoletes GA18 2488 1 Changes are made occasionally to the information herein any ...

Page 5: ...tation If you have any problems in setting up the IBM 3196 Display Statlon see the IBM 3196 Display Station Problem Solving Guide GA18 2483 Check each box 0 as you unpack and identify each item If any are missing call your IBM marketing representative Section 1 Inventorying the Elements 1 ...

Page 6: ...oVideo Element oVideo Stand o Keyboard o Keyboard Overlay o Logic Element o Auto Termination Unit 2 IBM 3196 Setup ...

Page 7: ... eoc hend ebgesch mt BescM umgungs nnu 9 unlet 20kV o Repair Identification RID Tags located on the underside of the logic element o Safety Label Spain Only NOABRIR SIN t ANTES OESCONEC TAR LA TENSION OERED m KV Il v 1E Hz 1iI W x Ml _ 1 Save all packaging material for use if service is required 2 Record the security key identification number in case the keys are lost and replacement is needed 3 S...

Page 8: ...4 IBM 3196 Setup ...

Page 9: ...nd Site Planning Guide GA21 9337 before seHing up your display station 2 1 ATTACHING THE TAGS TO YOUR VIDEO ELEMENT LOGIC ELEMENT AND KEYBOARD ELEMENT Note IBM uses the Repair Identification RID tags to determine the maintenance status of your display station Without these tags service may be delayed or unobtainable 2 1 1 Turn the logic element upside down Section 2 Setting Up the Display Station ...

Page 10: ...2 1 2 Remove the tags from the underside of the logic element Note The tags and their location may not appear exactly as shown I 2 1 3 Turn the logic element right side up 6 IBM 3196 Setup ...

Page 11: ...German Only Ole In d esem Ger 1 enlSlflFlende Flontvenst h1u i 51 lIu5 e Chend bgesch ml Besch leun iIun ilSSOllnnung unle 2010 V I I L _ _ _ _ _ _ J Front View r Spain Only I NO ABRIR SIN fill I I 7o C I I DE RED I KV I 1IJ v 1iI H 1il W I Bottom View Section 2 Setting Up the Display Station 7 ...

Page 12: ... 2 2 1 Place the circular portion of the video stand in the circular recess on top of the logic element and align the notch and tab 2 2 2 Pinch in the two latches to lock the video stand into the logic element then release the latches 8 IBM 3196 Setup ...

Page 13: ...2 2 3 Check the video stand to make sure it is securely locked into the logic element Section 2 Setting Up the Display Station 9 ...

Page 14: ...2 3 1 Turn the video element upside down Note Make sure the video screen faces you CJ D 0 1 1 UU J J _ _rr t J 1 rl m I lllllll 1lllllJ 1 1lI1111l1Il1LL _ m J1Illll 10 D l f 2 3 2 Locate the five slots on the bottom of the video element 10 IBM 3196 Setup ...

Page 15: ...the five hooks on the top of the video stand 2 3 4 Turn the logic element upside down and insert the five hooks on the video stand into the five slots on the video element Section 2 Setting Up the Display Station 11 ...

Page 16: ...d push the logic element forward in the same direction the screen faces until the video stand snaps into place 2 3 6 Make sure the video stand is locked into the video element by trying to move the logic element forward and backward 12 IBM 3196 Setup ...

Page 17: ...2 3 7 Turn the video element right side up o o Section 2 Setting Up the Display Station 13 ...

Page 18: ...then tighten the screws Note The video cable is permanently attached to some video elements 2 4 2 Remove the cap from the keyboard cable plug hold the plug so that the IBM logo is facing up then insert the plug into the socket on the front of the logic element Note Your keyboard may be different in appearance from the one shown 14 IBM 3196 Setup ...

Page 19: ...HE DISPLAY STATION FOR POWER ON 2 5 1 Make sure that the power switch is set to off 0 2 5 2 Insert the power cord plug into the power socket on the rear of the video element Section 2 Setting Up the Display Station 15 ...

Page 20: ...sible for the outlet and plug wiring If It becomes necessary to change power cord or plug or if the outlet is improperly wired have the change made according to local or national code A new power cord may be ordered from your IBM sales representative Notice For Customers in Chicago Illinois Two different lengths of power cords 1 8 m 5 9 ft and 2 8 m 9 2 tt are shipped with the IBM 3196 Display Sta...

Page 21: ...higher or lower position To adjust the keyboard to the higher position turn the keyboard upside down and flip the legs up from the underside of the keyboard To adjust the keyboard to the lower position push the legs into the underside of the keyboard Section 2 Setting Up the Display Station 17 ...

Page 22: ...2 6 2 Place the keyboard overlay on your keyboard 18 IBM 3196 Setup ...

Page 23: ...f n J I rtl 18111111 lel111 1 tUyw yl OiD U tll _IAI D F I 60006 IJl ll KPOAluuuuv TUVW 1 0D00091 2J 4 78ct3l tDj I 000000000000 000000000000 00 0000000000000 0 000 0000 00 0 000000000000 000 0000 00 0 0000000000000 0 0000 00 0 00000000000 0 000 0000 00 0 0 0 0 0 0 00 o 00 Note This AD error code is normal if this is the first time that the display station has been powered on since being shipped f...

Page 24: ...ideo element place your hands on both sides of the video element near the front edge and turn it left or right To tilt the video element place your hands on the upper back edge and front edge of the video element as shown above Then pull upward or push downward 20 IBM 3196 Setup ...

Page 25: ...To decrease the screen brightness turn the brightness control counterclockwise L Jj _ C 2 6 6 Adjust the screen contrast to a comfortable viewing level To increase the screen contrast turn the contrast control clockwise To decrease the screen contrast turn the contrast control counterclockwise l Section 2 Setting Up the Display Station 21 ...

Page 26: ...22 IBM 3196 Setup ...

Page 27: ...ocation and address of your IBM 3196 and any other workstation display station or printer that connects to the system or remote workstation controller The address for each workstation display station and printer must be different when workstations are connected together Some Important Points to Remember About Setup When you have more than one workstation display station or printer to set up and th...

Page 28: ...he IBM 3196 Display Station Problem Solving Guide Note Each workstation address for each display station and printer must be different when workstations are connected together Record your address here 3 1 2 Determine which keyboard you are using Does your keyboard look like this one YES NO You have the 122 key You have the t02 key keyboard keyboard Go to step 3 1 3 Go to step 3 1 10 24 IBM 3196 Se...

Page 29: ...isplay station address a number 0 through 6 you previously recorded on the front of your IBM 3196 Display Station Problem Solving Guide GA18 2483 appears to the right of the blinking diamond at the bottom of your display screen EXAMPLE o 1 Note If 9012 appears on the bottom of the display screen repeat step 3 1 4 Section 3 Display Station Configurations 25 ...

Page 30: ...3 1 5 Open the door on the right front of the logic element and store the IBM 3196 Display Station Problem Solving Guide GA18 2483 in the compartment Then close the door 26 IBM 3196 Setup ...

Page 31: ...display screen is a _If EXAMPLE o 1 Keyboard 10 Sample Only If the displayed keyboard 10 is 00 through 63 press the Keyboard 10 Cmd23 key until a _ If appears beside the display station address A _ If immediately follows the number 63 when the Keyboard 10 key is pressed Section 3 Display Station Configurations 27 ...

Page 32: ...em Do not select the multinational character set unless you consult your system operator 3 1 8 Press the Multinational Character Set Cmd 22 key to alternately enable disable the multinational character set When an M appears to the right of the blinking diamond at the bottom of your display screen the multinational character set is enabled EXAMPLE o M1 28 IBM 3196 Setup ...

Page 33: ...y The display station options are now set and will not be changed even if the display station power switch is set to off 0 Go to Section 4 Connecting to a Host System or a Controller Section 3 Display Station Configurations 29 ...

Page 34: ...3 1 10 Press and hold a Shift key then press the SetUp key A blinking diamond appears at the bottom of the display screen EXAMPLE o 30 IBM 3196 Setup ...

Page 35: ... Solving Guide GA18 2483 appears to the right of the blinking diamond at the bottom of your display screen EXAMPLE o Note If 9012 appears on the bottom of the display screen repeat step 3 1 11 3 1 12 Open the door on the right front of the logic element and store the IBM3196 Display Station Problem Solving Guide GA18 2483 in the compartment Then close the door Section 3 Display Station Configurati...

Page 36: ...n press the Keyboard ID F23 F11 key until a 00 appears beside the display station address A 00 immediately follows the number 31 when the Keyboard 10 key is pressed 3 1 14 Do you want to select the Multinational Character Set YES NO Go to step 3 1 15 Go to step 3 1 16 Note The Multinational Character Set is a function of your host system Do not select the multinational character set unless you con...

Page 37: ...er Set F22 F10 key to alternately enable disable the multinational character set When an M appears to the right of the blinking diamond at the bottom of your display screen the multinational character set is enabled EXAMPLE o M1 Section 3 Display Station Configurations 33 ...

Page 38: ...t key then press the SetUp key The display station options are now set and will not be changed even if the display station power switch is set to off 0 Go to Section 4 Connecting to a Host System or a Controller 34 IBM 3196 Setup ...

Page 39: ...MOTE WORKSTATION CONTROLLER REVIEW YOUR FLOOR PLAN SAFETY PRECAUTION Do not connect or disconnect cables during an electrical storm You could be seriously injured 4 1 1 Do the following 1 Set the power switch to off 0 2 Disconnect the power cord from the power outlet Section 4 Connecting to a Host System or a Controller 35 ...

Page 40: ...cable directly to your display station Always connect the communications cable to the auto termination unit 4 1 3 Locate the correct communications cable This may be the cable from the host system the workstation controller or the previous workstation 4 1 4 Align the widest slot in the cable plug with the key in either socket of the auto termination unit Then push the plug into the socket and turn...

Page 41: ...AY STATION L Example Only YES NO Go to step 4 1 6 Go to step 4 1 9 4 1 6 Connect the communications cable to the unused port on the workstation immediately before your IBM 3196 4 1 7 Does the workstation immediately before yours have a terminator switch See Appendix A for locations of terminator switches YES NO Go to step 4 1 8 Go to step 4 1 9 Section 4 Connecting to a Host System or a Controller...

Page 42: ... remote workstation controller be connected to a 5294 Control Unit 5294 CONTROL UNIT COMMUNICATION CABLE OTHER WORKSTATIONS YOUR DISPLAY STATION ______________Example Only ______________ YES Go to step 4 1 14 NO Make sure the communication cable is connected to the host system then go to step 4 1 10 4 1 10 Do the following 1 Connect the 3196 power cord to a grounded electrical outlet 2 Set the 319...

Page 43: ...IBM System 36 or performed reconfiguration for the IBM System 38 Does a sign on display similar to one of the two shown below appear Enter password to sigo on SIGN ON Optional User ID Password User menu libra ry Help Assistance for 5190 on WI COPYRIGHT 1984 IBH Corporation 2 2 06 56 Cursor System 38 System 36 YES NO Go to step 4 1 14 Go to step 4 1 13 Section 4 Connecting to a Host System or a Con...

Page 44: ...he correct address 2 Set the power switch to off 0 Then make sure that the cables on your display station are connected to the correct sockets and are securely fastened 3 If there is a workstation on the cable immediately before your IBM 3196 and it has a terminator switch make sure that the terminator switch is set to 2 See Appendix A in this guide for the locations of the terminator switches 4 S...

Page 45: ...Connect the second cable to the unused port of the auto termination unit The other end of this cable will connect to the next workstation on this cable CAUTION When a second cable is attached to the auto termination unit your IBM 3196 is automatically unterminated Do not connect the second cable unless the other end is connected to another workstation 4 1 17 Connect the 3196 power cord to a ground...

Page 46: ...4 1 18 42 Setup is complete on this display station If the communication cable will be connected to a 5294 Control Unit go to the IBM 5294 Control Unit Setup Procedure GA21 9369 ...

Page 47: ...wing illustrations show the location of the terminator switch on display stations Note Some display stations do not have a terminator switch 5251 Models 1 and 11 5291 Model 1 5291 Model 2 5292 Models 1 and 2 Appendix A Location of Terminator Switches 43 ...

Page 48: ...The following illustrations show the location of the terminator switch on printers 5219 lei I 5224 5225 5256 44 ...

Page 49: ...cked at the location to which this form is addressed Please direct any requests for copies of publications or for assistance in using your IBM system to your IBM representative or to the IBM branch office serving your locality Possible topics for comment are Clarity Accuracy Completeness Organization Coding Retrieval Legibility If you wish a reply give your name company mailing address and date Wh...

Page 50: ...d and tape 1111 1 1 ij IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS PERMIT NO 40 ARMONK N Y POSTAGE WILL BE PAID BY ADDRESSEE International Business Machines Corporation Dept 6R1 J 180 Kost Road Mechanicsburg PA 17055 Fold and tape Please Do Not Staple Fold and tape ...

Page 51: ......

Page 52: ...GA18 2488 2 Part Number 81 X5374 File Number S5250 36 38 06 GA18 2488 2 _ ...

Reviews: