Configuring the Triton T1/E1 Board
MAXCS ACM 6.7 Administration Manual 147
Reading the Statistics
The
Statistics
panel displays the number of errors that have occurred since the last
system reboot or statistics clearing. There may be non-zero values when configuring the
T1 span for the first time. You can clear these fields with the
Clear
button.
Note:
For ideally synchronized systems,
Transmit
and
Receive
Frame Slips
counters
should be ‘0.’ Continuous update of the frame slips counters means that transmit
and receive frequencies are not equal. In this case, you should check the system
and CT-Bus clock setup.
L1 failure: <Red
Alarm>
Layer 1 failure, physical
layer; Bi-Polar Violations
(BPV), Line Code Violations
(LCV), or Out Of Frame
detected
Location condition, equipment
problem.
- For excessive BPV/LCV, check
AMI/B8ZS setting.
- For OOF, check the MVIP bus
master setting.
OR
Have CO perform a line test to
check for a faulty cable or line.
[PRI only]
L2 Failure: <No Sync
Flag>
Layer 2 failure, data link
layer; no sync flag has been
detected in data link layer
Check if D-channel is active or
not
[PRI only]
L2 Failure: <Not
established>
Layer 2 failure, data link
layer; the peer-to-peer link
has not established in data
link layer
CO must activate HDLC link
Error
Meaning
Frame Errors
Number of framing bit errors. In T1 mode, a framing bit
error is defined as an incorrect FS-bit value. The counter is
suppressed when framer loses frame alignment
OOF Errors
The Out Of Frame counter registers every time the T1 chip
is forced to re-frame when receiving a frame with severe
errors.
Rec Frame Slips
The Receiver Frame Slips counter shows the number of
frame slips for the receiver.
Line Code Errors
Line Code Error is defined as an occurrence of a bi-polar
variation or excessive zeroes.
Bit Errors
Bit Errors are defined as a CRC-6 error in ESF, FT-bit
error in SLC-96 and F-bit or sync bit error in SF.
Xmt Frame Slips
Transmit Frame Slips counter shows the number of
frame slips for the transmitter
Clear
button
Use the
Clear
button to reset the statistics counters.
Error Message
Meaning
Action
Summary of Contents for ACM 6.7
Page 1: ...MAX Communication Server Administration Manual ACM 6 7 September 2011 ...
Page 16: ...2 MAXCS ACM 6 7 Administration Manual ...
Page 32: ...Overview 18 MAXCS ACM 6 7 Administration Manual ...
Page 46: ...Troubleshooting Error Messages 32 MAXCS ACM 6 7 Administration Manual ...
Page 58: ...Programs Available from the Windows Start Menu 44 MAXCS ACM 6 7 Administration Manual ...
Page 92: ...Configuring the Applications Server 78 MAXCS ACM 6 7 Administration Manual ...
Page 100: ...Creating Distribution Lists 86 MAXCS ACM 6 7 Administration Manual ...
Page 110: ...Phrase Management 96 MAXCS ACM 6 7 Administration Manual ...
Page 128: ...Application Extension Setup 114 MAXCS ACM 6 7 Administration Manual ...
Page 152: ...Outgoing Call Blocking 138 MAXCS ACM 6 7 Administration Manual ...
Page 180: ...Configuring the Virtual MobileExtSP Board 166 MAXCS ACM 6 7 Administration Manual ...
Page 186: ...DNIS Routing 172 MAXCS ACM 6 7 Administration Manual ...
Page 226: ...Setting Up Monitor Lists 212 MAXCS ACM 6 7 Administration Manual ...
Page 234: ...Setting an IP Extension 220 MAXCS ACM 6 7 Administration Manual ...
Page 254: ...Mobile Extension Limitations 240 MAXCS ACM 6 7 Administration Manual ...
Page 272: ...258 MAXCS ACM 6 7 Administration Manual ...
Page 364: ...When Information May Be Out of Sync 350 MAXCS ACM 6 7 Administration Manual ...
Page 380: ...Limitations 366 MAXCS ACM 6 7 Administration Manual ...
Page 406: ...Notes 392 MAXCS ACM 6 7 Administration Manual ...
Page 414: ...Changing TAPI Configuration Parameters 400 MAXCS ACM 6 7 Administration Manual ...
Page 456: ...442 MAXCS ACM 6 7 Administration Manual ...