9
Press
Sync Now
and then
Auto Align
to find the optimum sampling point. Check
that the synchronization and the alignment were successful. None of the error
indicators should show red, and the resulting BER should be zero.
How to Execute the Spectral Jitter Measurement
To run the Spectral Jitter measurement:
1
Switch to the
Analysis
area. If the
Spectral Jitter
screen is not yet displayed,
press the
Spectral Jitter
icon.
2
Press the
Start
button to execute the measurement.
The measurement software runs the measurement and displays the results. A total
of 65535 points are displayed for this measurement.
Numerical values are also displayed. The values include
Bit Error Rate
,
Total
Power
, and
Noise power
. Additionally, you can also configure up to 16 frequency/
power pairs. The latter are sorted according to descending power contents. These
“Explanation of the Numerical Results” on page 259
How to Optimize the View of the Results
After you have run a measurement, the resulting graph and the calculated
numerical values are displayed. To improve the results, you can change the
measurement parameters:
1
Press the
Properties
button to open the
Properties
dialog box.
2
Use the different tabs in this dialog box to make the required settings:
–
Parameters
tab
6
Advanced Analysis
352
Agilent J-BERT N4903B High-Performance Serial BERT
Summary of Contents for J-BERT N4903B
Page 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Page 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Page 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Page 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Page 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Page 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Page 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Page 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Page 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...