• Fill with Ones
• Invert. The Invert does the following functions:
Symbol Mode off: Invert the bits.
Symbol Mode OOB: 0 becomes 1, 1 becomes 0, Z remains unchanged.
Symbol Mode PAM4: Invert bits on per channel basis.
• Clock Pattern 0101…0101
• Clock Pattern divide by
• Symbol
N O T E
All the above options are not available in all modes. The
Symbol fill is available if
the
Symbol Mode is enabled.
N O T E
In PAM4 mode the symbol that is used for a ‘0’ is ‘00’ and for a '1' it is ‘11’. This
will be used for Fill with 0, Fill with 1 and for the Clock pattern Fills.
2
Recode
This tab is used to change the coding of a selected range in the pattern.
The button
Convert undefined to Z
provides an easy access to fix all undefined
symbols to the coding of a Z symbol. It is only accessible when symbol mode
is set to OOB, as there is no undefined symbol in PAM4 mode.
Setting up Patterns
3
Agilent J-BERT N4903B High-Performance Serial BERT
87
Summary of Contents for J-BERT N4903B
Page 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Page 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Page 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Page 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Page 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Page 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Page 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Page 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Page 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...