Illegal Symbol Count (Illegal symbol counter)
The total number of illegal symbol count received in a time interval is displayed
here.
•
Disparity Error Ratio (DER)
The ratio of the number of illegal disparity change count to the number of
symbols received in the current (or last completed) accumulation period,
specified by the gate period is displayed here.
The following is the expression used to calculate the Disparity Error Ratio:
•
Filler Symbol Ratio (FSR)
The ratio of the number of filler symbol count to the number of symbols received
in the current (or last completed) accumulation period, specified by the gate
period is displayed here.
The following is the expression used to calculate the Filler Symbol Ratio:
•
Illegal Symbol Ratio (ISR)
The ratio of the number of Illegal Symbol count to the number of symbols
received in the current (or last completed) accumulation period, specified by
the gate period is displayed here. Illegal Symbol are invalid K and D symbols
i.e. 0000000000 it does not belong to any valid K or D symbols.
The following is the expression used to calculate the Illegal Symbol Ratio:
•
Expected Filler Symbol Count
The total number of Expected Filler Symbol Count received in a time interval is
displayed here.
The following is the expression used to calculate the Expected Filler Symbol
Count:
•
Data Rate Ratio
The ratio of the number of filler symbol count to the expected filler symbol count
received in the current (or last completed) accumulation period, specified by
the gate period is displayed here.
Evaluating Results
7
Agilent J-BERT N4903B High-Performance Serial BERT
387
Summary of Contents for J-BERT N4903B
Page 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Page 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Page 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Page 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Page 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Page 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Page 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Page 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Page 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...