Code
Description
Brake Operation Sequence in “Vector”
control Mode
<Brake release sequence>
When an operational command is entered, the output relay or
multi-function output terminal for brake control sends a brake
release signal after the pre-excitation time is passed. Once the
signal has been sent, acceleration will begin after the brake release
delay time (ADV-42 BR Rls Dly) has passed.
<Brake engage sequence>
If a stop command is sent during operation, the inverter
decelerates to “0 Hz” and sends out a
brake engage signal. Then,
the output is cut off after the brake engage delay time (ADV-46 BR
Eng Dly) has passed.
The brake engage sequence does not operate in torque control
mode.