Learning Advanced Features
272
8.33
Config (CNF) Mode
The config mode parameters are used to configure keypad-related features.
Group Code Name
LCD Display
Parameter Setting Setting Range Unit
CNF*
2
LCD brightness/
contrast adjustment
LCD Contrast
-
-
10
Inverter S/W version
Inv S/W Ver
x.xx
-
11
Keypad S/W version
Keypad S/W Ver x.xx
-
-
12
Keypad title version
KPD Title Ver
x.xx
-
-
30
–
32 Power slot type
Option-x Type
None
-
-
41
Display changed
parameters
Changed Para
0
View All
0
–
1
-
44
Erase trip history
Erase All Trip
No
-
-
60
Add title update
Add Title Up
No
-
-
62
Initialize accumulated
electrical energy
WH Count
Reset
No
-
-
74
Accumulated cooling
fan operation time
Fan Time
0000DAY 00:00
75
Accumulated cooling
fan operation time
initialization
Fan Time Rst
0 No
Config Mode Parameter Setting Details
Code
Description
CNF-2 LCD Contrast
Adjusts LCD brightness/contrast on the keypad.
CNF-10 Inv S/W Ver,
CNF-11 Keypad S/W Ver
Checks the OS version in the inverter and on the keypad.
CNF-12 KPD Title Ver
Checks the title version on the keypad.
CNF-30
–
32 Option-x Type Checks the type of option board installed in the option slot.
CNF-41 Changed Para
Displays all the parameters that are different from the factory defaults.
CNF-44 Erase All Trip
Deletes the stored trip history.
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...