Basic Functions
181
B
as
ic
Func
tio
ns
Group Code Name
LCD Display
Parameter Setting
Setting Range Unit
17
Rev Boost
Note2)
Rev Boost
2.0
0-15
%
26
Adv ATB Filter
Adv ATB Filter
100
1-1000
msec
27
Adv ATB M Gain
Adv ATB M Gain 50.0
0-300.0
%
28
Adv ATB G Gain
Adv ATB G Gain 50.0
0-300.0
%
*
Note 1, Note 2) For 90 kW
–
160 kW products, the factory shipment value is 1.0 [%].
Advanced Auto Torque Boost Setting Details
Code
Description
DRV-16 Fwd Boost
Adjusts the torque boost amount for forward rotation
DRV-17 Rev Boost
Adjusts the torque boost amount for reverse rotation.
DRV-26 Adv ATB Filter
Filter gain for calculating the Auto Torque Boost value.
DRV-27 Adv ATB M Gain
Gain for calculating the reverse Auto Torque Boost value.
DRV-28 Adv ATB G Gain
Gain for calculating the regeneration Auto Torque Boost value.
If there is no load, the additional voltage amount due to Auto Torque Boost is 0, which gives
the same result as the normal manual boost.
When the load is applied, the amount of compensation voltage varies depending on the
operation and reverse directions.
If you set the DRV-16 and DRV-17 values differently when using Advanced Auto Torque Boost
at no load, a current hunting operation may occur.
Output voltage = Primary output v Secondary output voltage
Primary output voltage
= Output voltage affected by DRV-16,17 Manual torque boost parameter
=
(𝑀𝑎𝑥𝑖𝑚𝑢𝑚 𝑣𝑜𝑙𝑡𝑎𝑔𝑒 – 𝐵𝑜𝑜𝑠𝑡𝑒𝑑 𝑣𝑜𝑙𝑡𝑎𝑔𝑒) ×
𝐶𝑢𝑟𝑟𝑒𝑛𝑡 𝑓𝑟𝑒𝑞𝑢𝑒𝑛𝑐𝑦
𝐵𝑎𝑠𝑒 𝑓𝑟𝑒𝑞𝑢𝑒𝑛𝑐𝑦
+ 𝐵𝑜𝑜𝑠𝑡𝑒𝑑 𝑣𝑜𝑙𝑡𝑎𝑔𝑒
Secondary output voltage
= Output voltage affected by DRV-27,28 ATB M/G Gain parameter and motor load
=
𝑀𝑜𝑡𝑜𝑟 𝑟𝑎𝑡𝑒𝑑 𝑠𝑙𝑖𝑝 𝑓𝑟𝑒𝑞𝑢𝑒𝑛𝑐𝑦 ×
𝑀𝑜𝑡𝑜𝑟 𝑚𝑎𝑥 𝑝ℎ𝑎𝑠𝑒 𝑣𝑜𝑙𝑡𝑎𝑔𝑒
𝐵𝑎𝑠𝑒 𝑓𝑟𝑒𝑞𝑢𝑒𝑛𝑐𝑦
× 𝐴𝑇𝐵 𝑀/𝐺 𝐺𝑎𝑖𝑛 ×
𝐶𝑢𝑟𝑟𝑒𝑛𝑡 𝑜𝑢𝑡𝑝𝑢𝑡 𝑐𝑢𝑟𝑟𝑒𝑛𝑡
𝑀𝑜𝑡𝑜𝑟 𝑟𝑎𝑡𝑒𝑑 𝑐𝑢𝑟𝑟𝑒𝑛𝑡
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...