![LS ELECTRIC SV-iS7 Series Скачать руководство пользователя страница 294](http://html1.mh-extra.com/html/ls-electric/sv-is7-series/sv-is7-series_user-manual_1943801294.webp)
Learning Advanced Features
Adv
anc
ed
Feat
ur
es
277
Code
Description
For example, sequence-
2 begins operation with the set frequency at “Seq
2/1 Freq.”
AUT-11 Seq 1/1 XcelT
Sets the acceleration or deceleration time for the step. Acceleration or
deceleration times indicate the time it takes for the operation frequency
to transit to the next step frequency.
AUT-12 Seq 1/1 StedT
Sets the time duration for the inverter to maintain the reference
frequency set at AUT-10.
AUT-13 Seq 1/1 Dir
Sets the rotational direction for the step.