203
8.2.3
Jog Operation via Keypad Input
The jog operation is available using the keypad input as well.
The priorities for the frequency, acc/dec time, and terminal block input during an operation in
relation to other operating modes (Dwell, 3-wire, up/down, etc.) are identical to jog operations
using the terminal input.
Group Code Name
LCD Display
Parameter setting Setting Range
Unit
DRV
11
Jog frequency
JOG Frequency
10.00
0.5
–
Max Freq
Hz
12
Jog operation
acceleration time
JOG Acc Time
20.00
0.00
–
600.00
sec
13
Operation
deceleration time
JOG Dec Time
30.00
0.00
–
600.00
sec
The table below lists parameter settings for a forward jog operation using the keypad input.
MODE
Group
Code
LCD Display
Parameter Setting
Setting Range
Unit
CNF
-
42
Multi-Key Sel
1
JOG Key
-
-
PAR
DRV
06
Cmd Source
0
Keypad
0
–
5
sec
After setting CNF-42 to
“1
(JOG Key)
”
and DRV-06 (in PAR mode) to
“0
(Keypad)
”
, you can start
the jog operation using the keypad by pressing the [MULTI] key on the keypad.
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...