Frequency Hold by Analog Input
If you set a frequency reference via the analog input at the control terminal block, you can hold
the operation frequency of the inverter by assigning a multi-function input as the analog
frequency hold terminal. The operation frequency will be linked to the analog input signal.
Group Code Name
LCD Display
Parameter Setting Setting Range Unit
DRV
07
Frequency reference
source
Freq Ref Src
0
Keypad-1
0
–
9
-
1
Keypad-2
2
V1
3
I1
4
V2
5
I2
6
Int 485
7
Encoder
8
Field Bus
9
PLC
IN
65
–
75
Px terminal
configuration
Px Define(Px:
P1
–
P8
[optional: P9
–
P11]) [Optional
P9
–
11]
21 Analog Hold 65
–
75
-