Communication Function
374
Address Parameter
Scale unit Assigned content by bit
B7
0001(1): Speed search
0010(2): Accelerating
0011(3): Steady speed
0100(4): Decelerating
0101(5): Decelerating stop
0110(6): H/W OCS
0111(7): S/W OCS
1000(8): Dwell operating
B6
B5
B4
B3
0000(0): Stop
0001(1): Forward operating
0010(2): Reverse operating
0011(3): DC operating (0 speed control)
B2
B1
B0
0h0306
Inverter run frequency
command source
-
-
B15
Run command source
00000000(0):Keypad
00000001(1):Communication option
00000010(2):App/PLC
00000011(3):Built-in 485
00000100(4):Terminal Block
00000101(5):reserved
00000110(6):Auto 1
00000111(7):Auto 2
B14
B13
B12
B11
B10
B9
B8
B7
Frequency command source
00000000(0):Keypad speed
00000001(1):Keypad torque
00000010~00000100(2~4):Up/Down
run speed
00000101(5): V1 00000110(6): I1
00000111(7): V2 00001000(8): I2
00001001(9): Pulse
00001010(10):Bulit-in 485
00001011(11):Comm option
00001100(12): App(PLC)
00001101(13): Jog 00001110(14): PID
00001111~00010110(15~22) : Auto Step
00011001~00100111(25~39) : Multi-
step speed frequency
B6
B5
B4
B3
B2
B1
B0
0h0307 Keypad S/W version
-
-
Ex.) 0x0100: Version 1.00
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...