Learning Advanced Features
242
Code
Description
CON-11 Hold Time
When a run command stops, the inverter holds the zero speed output
for the set time before the motor decelerates to a complete stop.
8.14
Torque Control
You can use torque control to operate the inverter to produce a certain amount of torque as
indicated by the torque reference. In torque control mode, the motor speed is decided by the
amount of load because a motor can run at a constant speed when the output torque and
torque load are equal. The motor speed increases when the output torque becomes greater
than the torque load. You can set a speed limit to maintain the motor speed within a certain
range. Note that torque control is not available during the speed control operations.
Group Code Name
LCD Display
Parameter Setting
Unit
DRV
02
Torque command
Cmd Torque
-
0.0
%
08
Torque reference source
Trq Ref Src
0
Keypad-1
-
09
Control mode
Control Mode
5
Vector
-
10
Torque control
Torque Control
1
Yes
-
BAS
20
Auto tuning
Auto Tuning
1
Yes
-
CON
35
SL2 L-ExcitLmt
SL2 L-ExcitLmt
-
10
%
62
Speed limit setting options
Speed Lmt Src
0
Keypad-1
-
63
Forward speed limit
FWD Speed Lmt
-
60.00
Hz
64
Reverse speed limit
REV Speed Lmt
-
60.00
Hz
65
Speed limit operation gain
Speed Lmt Gain
-
500
%
IN
65
–
75 PX terminal function setting Px Define
35 Speed/Torque
-
OUT
31
–
33
Multi-function relay,
Multi-function output 1
Relay x or Q1
27 Torque Dect
-
59
Detected torque amount
TD Level
-
100
%
60
Detected torque width
TD Band
-
5.0
%
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...