Learning Advanced Features
258
8.22
2nd Motor Operation
The 2
nd
motor operation is used when a single inverter switch operates two motors. Using the
2
nd
motor operation, a parameter for the second motor is set. The second motor operates
when a multi-function terminal input defined as a second motor function is turned on.
Group Code
Name
LCD Display
Parameter Setting Setting Range Unit
IN
65
–
75
Px terminal
configuration
Px Define(Px: P1
–
P8
[optional: P9
–
P11])
26
2nd Motor -
-
M2
04
2nd motor
acceleration
time
M2-Acc Time
-
5.0
0
–
600
sec
2
nd
Motor Operation Setting Details
Code
Description
IN-65
–
75 Px
Define
Set one of the multi-function input terminals (P1
–
P11
) to “26 (2nd Motor)” to
display the M2 (2nd motor group) group. An input signal sent to a multi-
function terminal set as the second motor will operate the motor according to
the code settings listed below. However, if the inverter is in operation, input
signals to the multi-function terminals will not read as a second motor
parameter.
•
You can set the 2nd motor control mode at M2-08 (M2-Ctrl Mode). V/F PG
and Vector control modes are not supported with the 2nd motor
operation.
•
PRT-50 (Stall Prevent) must be set first, before M2-28 (M2-Stall Lev)
settings can be used.
•
PRT-40 (ETH Trip Sel) must be set first, before M2-29 (M2-ETH 1 min) and
M2-30 (M2-ETH Cont) settings can be used.
Parameter Setting at Multi-function Terminal Input on a Second Motor
Code
Description
Code
Description
M2-04 Acc Time
Acceleration time
M2-15 M2-Efficiency Motor efficiency
M2-05 M2-Dec Time
Deceleration time
M2-17 M2-Rs
Stator resistance
M2-06 M2-Capacity
Motor capacity
M2-18 M2-Lsigma
Leakage inductance
M2-07 M2-Base Freq
Motor base frequency M2-25 M2-V/F Patt
V/F pattern
M2-08 M2-Ctrl Mode
Control mode
M2-26 M2-Fwd Boost Forward torque boost
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...