
KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 96 -
PARAMETER : LIFT BUS
After market introduction of the device SAG-90 it is possible that the controller communicates by bus
with control.
PARAMETER : WARM UP DRIVE
With this parameter you can operate the termpetature input (Assigned with function E492 temperatur
Warm Up Drive). A drive starts to warm up the oil.
PARAMETER : WARM UP DRIVE AFTER XX MINUTS
In this parameter you can choose the start time of the Warm Up Drive. Start time is always after lower
drive. The maximum time is 1250 minutes.
B31 – Hydraulic Regulated
PARAMETER: START
In this parameter, you can choose two values, namely “Star/ Delta “ and “ Softstart”.
PARAMETER: S/D-REVERSE TIME
This parameter represents the reverse time between star-protection and triangle-protection. The
standard value is 2 seconds.
PARAMETER: COMMAND UP DELAYED ON
If you activate this parameter, you can switch on the up-command with a delay-time. The standard value
is 100 ms. You need this function in connection with Bucher-LRV-Regelkarten.
PARAMETER: DIRECTION UP DELAYED
The parameter has an option to switch on retarded the up direction. The standard value is NO.
PARAMETER: COMMAND UP DELAYED
If you activate this parameter, you can switch off the up-command with a delay-time. The standard value
is 400 ms.
PARAMETER: START WITH DOOR CONTROLLING
If you activate the parameter, you can start the hydraulic-pump in the same time how the motion to close
the door begins. In the standard-parameter set the function is not activated.
PARAMETER: INSPECTION SPEED
Speed:
1- Speed slow
2- Speed Vi
3- Speed high
PARAMETER: TIME TO GO DOWN
The hydraulic elevator must lower late after first of all 15 minutes to the lowest stop place. The time is
adjustable by this parameter.
PARAMETER: FAULT HANDLING
By the menu attitude can be selected, as the control has to react to error messages of the regulation.
a) “NO”- regulation does not have a disturbance exit.
b) “STOP + LOWERING”- If there is an error in the regulation, the driving instructions are
taken back and the calls are deleted. The car is lowered into the lowest stop place.
PARAMETER: TRAVEL DOWN AT OVERLOAD
Is overload in the car it must be decided at expiration of the sinking time whether lower or not. The
standard value is NO.
PARAMETER: SIGNAL TOP OF RAMP
After eaching „the Top Of the Ramp“ on the softstart unit approach equipment this further announced
to the regulation. During the attitude of kind of condition this parameter is active.
PARAMETER: COMMAND DOWN DELAYED ON/OFF
The parameter contains the alternative to switch strainghtening on retarded. This is needed with the
employment of a return flow prevention valve ( e.g.ALGI-S5). The standard value is NO.
PARAMETER: DETENT END SWITCH TOP
In this parameter you can choose if the elevator blocks after leaving upper end switcher and the following
emergency sinking. Default value is YES.
PARAMETER: LIFT BUS
After market introduction of the device SAG-90 it is possible that the controller communicates by bus
with control.
Parameter: Warm Up Drive
With this parameter you can operate the termperature input (Assigned with function E492 temperature
Warm Up Drive ). A drive starts to warm up the oil.
Parameter: Warm Up Drive after XX minuts
In this parameter you can choose the start time of the Warm Up Drive. Start time is always after lower
drive. The maximum time is 1250 minutes.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...