KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 102 -
B35- Robe Variable Frequency
1.0 Contactor Switching
In principle the frequency-regular rope elevator needs four vat signals.
Bez.
Pre-control
Rope Frequency Mana-
ged
Robe Variable Frequency
5
K31
K3 Drive Contactor
K1 Up Contactor
3
K32
K3 Drive Contactor
K2 Down Contactor
7
K33
K5 Main Contactor
K5 Main Contactor
9
K34
K7-Brake Contactor
K7Brake Contactor
The driving instructions are similar to those with tension-regular plants.
Term
Rope Frequency Regulated
Robe Variable Frequency
AB
Direktion Up
Direktion Up
AUF
Direktion Down
Direktion Down
Vins
Speed Vins
Speed Vins
Vn
Speed Vn
Speed Vn
V0
Speed V0
Speed V0
V1
Speed V1
Speed V1
V2
Speed V2
Speed V2
V3
Speed V3
Speed V3
PARAMETER: LIFT BUS
In the case of activation of the parameter regulations ( frequency inverter ) can communicate over RS
485 connection with the controller. The change-over between the display of the frequency inverter and
the control is made by a combination of keys at the HPG60: The left key must remain pressed and then
the lowest key is pressed. As selectable software programs are available: the KW liftbus and DCP-3.
The following inverters ar tested and the communication is stable:
Ziehl-Abegg
Zetadyn 2CF/ 2CS 3BF / 3CS & 4xx
authorization DCP-3
Emerson / CT
Commander SP mit DCP-Schnittstelle
authorization DCP-3
Liftequip / ThyssenKrupp MFC 20 bzw. MFC 30/31
authorization DCP-3
PARAMETER: MOTOR FAN
A free-provable exit of the central unit can be selected for the engine ventilation. The attitude of the time
is adjustable in the menu.
PARAMETER: V0 DELAYED OFF
The parameter contains the attitude to switch off the speed V0 retarded. The standard value is NO.
PARAMETER: DIRECTION DELAYED OFF
Time-delayed will the removal of the driving direction, in order to ensure stopping without jerking. The
deceleration time is adjustable in the menu. As default value is deposited 2500 ms.
PARAMETER: MAIN CONSTRUCTOR DELAYED OFF
The driving contactors must become retarded turning-off, in order to hold the car with number of revo-
lutions 0, until the brake contactor drops. The standard value is 2500 ms.
PARAMETER: REVELING SPEED
In this parameter you can put in the speed for releveling. You can choose VN or V0.
PARAMETER: FAULT HANDING
In this parameter you can choose the reaction of the controller, if there is a fault in the inverter-part.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...