B612 Rescue Travel
This function is used, among other things, to rescue people with disabilities in the event of a fire. In
principle, this function can also be used to evacuate people in buildings.
There are two variants available:
A) The elevator is made available in a fixed collecting level for a certain length of stay and then moves
to the rescue level with the people to be evacuated. After emptying the car on the rescue level, the
elevator returns to the collective level. This process can be repeated up to 10 times, depending on
the setting.
B) In the second variant, evacuation takes place without a fixed collection level, but the rescue trips are
dependent on the existing external calls. With this setting, the landing calls are saved and ap-
proached individually, i.e. after each landing call, the rescue level is approached and then the level
of the next landing call is approached. The rescue trip is carried out starting with the furthest outside
calls in relation to the rescue level to the next outside calls. It is also possible to name
one to three
collective levels with different priorities
. This means that floors with people with disabilities can
be evacuated preferentially. The rescue operation is ended by:
1.) Active smoke detector on the rescue level
2.) Active smoke detector in the elevator control
Parameter Rescue Travel
In this parameter you can activate the rescue drive.
Parameter Collective Floor
The connection floor is in the software free chooseable. At this level, the saving of people the opportunity
to enter the elevator car.
In addition, the "Outside Call" setting is possible. With this setting, the outside
calls are stored and started individually, i.e. after each called out call, the rescue level is approached
and then treated the next outcry.
Parameter Collective Floor Wait Time
T
his time period allows the boarding of persons to be rescued in the elevator car. The dwell time is
adjustable between 1 and up to 15 minutes. Five seconds before closing the door will sound the buzzer
on the inner panel computer EIT. The photocell is not observed, only the reverse-contact of the door.
Parameter Rescue Floor
The rescue floor is mainly the main floor. There should be a barrier-free and rapid evacuation of persons
guaranteed.
Parameter Rescue Floor Wait Time
T
his time period allows the outboarding of persons to be rescued in the elevator car. The dwell time is
adjustable between 1 and up to 15 minutes. Five seconds before closing the door will sound the buzzer
on the inner panel computer EIT. The photocell is not observed, only the reverse-contact of the door.
Parameter Rescue Travel Repeat Travel
By entering a number between 1 and 10 in this parameter, it is possible to repeat the process of recovery
journey.
Parameter: Open Doorside
The door position after arriving at the rescue level can be set in this parameter. If there is only one side
of the door, the door is always open. If there are two door sides, a decision can be made as to whether
door side 1 or door side 2 or door side 3 are open.
Parameter: Collective Level Prio 1
The collective level with priority 1 is determined in this parameter.
Parameter: Collective Level Prio 2
The collective level with priority 2 is determined in this parameter.
Parameter: Collective Level Prio 3
The collective level with priority 3 is determined in this parameter.
B613 GUIDE MODE
Guide mode operation is activated by permanently applying a signal to input function E23. At the same
time, the feedback "Operator operation active" is output to output function A37.
Parameter Guide mode
Guide mode can be activated in this parameter.
Parameter Guide mode - door control
This parameter can also be used to set whether the door control should take place automatically or
manually. With automatic door control, the door closes automatically after entering an internal call,
with manual door control, after entering an internal call, the door CLOSE button must be pressed until
the door closes completely. The light barrier is not evaluated here. If the door CLOSE button is re-
leased before the door is completely closed, the door opens again.
Parameter Guide mode - delete landing calls after
In this menu it can be set whether the external calls are deleted after a certain time (1-60 minutes) if
they have not been started during this time.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...