KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 44 -
FUNCTION-VISUALISATION
When the ER-2013/2014 is connected to the bus line and the con-
trol is active, the green LED blinks. In short circuit on the busline
or malfunction expires or lights the LED. You can control the Re-
mote Station in Menu C6 Modul Monitor/ Remote Station ER01-16
and Remote Station ER 17-32.
For every remote station with an acceptable function, there will
be shown an „
E
“ in the display of the HPG-60. From left to right,
you can see in the display all remote stations from the first floor
to the hightest floor which are recognized in the system.
ADRESS SETTING
All ER-2013 preset for the individual floors. The bottom floor has
always marked “Floor 01”. The setting of floors is no longer adress
switch on the Remote Station, like ER-2005, but by the setting soft-
ware.
1. STEP:
Switch off the controller (
Main Switch Q1, and
Fuses F6 & F7 switch off
).
2. STEP:
The Remote Station programmed with the RJ-45 cable
with the central unit. All other Remote Stations may not be con-
nected.
3. STEP:
It must be set a jumper on the 5-pin socket Print be-
tween pins 2 and 3 (-> see picture left). Then, the system can be
put under power (main switch Q1, Q6 is switched on).
4. STEPt:
You can regulate the parameter “Remote Station
Adress programming” in menu C6 Modul Monitor. The ER-2013
gets his adress with the selection of the number of floors. (01-64).
Then the ER-2014 can be installed in the corresponding floor.
TERMINAL: MATRIX-INDICATOR TYPE ANZ-xx
The connection of the Matrix-indicator of type ANZ-XX (ANZ-22,
ANZ-32, ANZ.-33, ANZ-52 & ANZ-53) takes place on the black
RJ-12 jack with the black RJ-12 cable.
Don’t do the RJ-12 in the silber RJ-45 jack!
Connection of a TFT-Displays at an ER-2013
The connection of TFT displays is done by the yellow RJ-
12 jack with the included RJ-12 cable.
The RJ-12 cable
is not allowed to be plugged
into the
RJ-45 jack silver or in one of the two RJ12 sockets for
matrix display!
Connection of several TFT-Displays at an
ER-2013
Several TFT displays can be operated at a terminal by
means of a RJ-12 splitter.
This is necessary in elevator installations with several
door sides, or in elevator groups.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...