B628 Penthouse Control
General:
The penthouse control unit in development 03-2017 serves 8 penthouse residential units. All an-
nouncements for penthouse control are evaluated with the central computer D613 in the machine
room.
The interior calls for the penthouse floor are encrypted (e.g., via a card reader or 10-key key-
board).
Car-Call Penthouse-Apartment:
In general, the car call of the penthouse floor via the input function E368 ... E431, E765 ... E956 (call
blocking in-car call, setting B606: Dynam. Lockout: only intercom calls) is blocked and is released by
the penthouse resident via a key switch or access control (eg RFID) if he wants to drive to his apart-
ment.
Visitor-Control:
The cabin will only be sent in the floor if it is empty ->(E437 = 1).
Priority-Call in the Apartment:
The cabin will only be sent in the floor if it is empty ->(E437 = 1)
In the menu "B628 penthouse control" all settings of the penthouse control are made. At present, a
maximum of 8 penthouse apartments are planned (Penthouse-X: 1 ... .8). For each penthouse apart-
ment the following settings are available:
B628 Penthouse-X: -OFF- / Floor: XY
B628 Penthouse-X: Doorside-1/2/3
B628 Penthouse-X: Visitor: Calls / automatic
For each of the existing penthouse apartment first the corresponding floor and the door side must be
set. Furthermore, there is the choice of whether in the visitor attention of the car call in the pent-house
floor manually (released floor flashes) or automatically (by interrupting the light barrier, the interior call
is set to the penthouse) is triggered.
The car calls to the corresponding penthouse floors must be coded using the input functions "Call Bar-
ring Internal Calls TX HSxy" (input functions E368 - E399, E765 - E860).
The corresponding car calls can be released via a key-operated switch or a reader (when the visitor
picks up, the internal call is released by the control in the main access level).
In the menu "B607 car call release feedback: off / flashing" it can be selected whether the enabled
internal call to the identification flashes.
In general, the controller must be in normal operation. By activating a pent-up call described below, the
landing calls are blocked, the car calls are canceled (if available) and then the selected penthouse call
is carried out. After completion of the recovery either another penthouse recovery is carried out (if it was
triggered in another penthouse apartment) or switched back to normal operation. There is an internal
FIFO memory which internally stores all penthouse requirements (currently 10 penthouse apartments)
and processes them in sequence.
The following penthouse modes are provided:
1. Penthouse-Priority-call of the penthouse apartment
A
. The apartment owner presses the call for recovery of the cabin in his apartment:
Inputfunction E742 – Priority-call Penthouse -1
Inputfunction E745 – Priority-call Penthouse -2
Inputfunction E748 – Priority-call Penthouse -3
Inputfunction E751 – Priority-call Penthouse -4
Inputfunction E754 – Priority-call Penthouse -5
Inputfunction E757 – Priority-call Penthouse -6
Inputfunction E760 – Priority-call Penthouse -7
Inputfunction E763 – Priority-call Penthouse -8
Inputfunction E990 – Priority-call Penthouse -9
Inputfunction E993 – Priority-call Penthouse -10
B
. The call in indicated over:
Outputfunction A575 Indication Penthouse-1
Outputfunction A577 Indication Penthouse-2
Outputfunction A579 Indication Penthouse-3
Outputfunction A581 Indication Penthouse-4
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...