KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 207 -
F130
Monitor Brake-1:
-
Brake-circuit-1 does not open / closed during the travel -> Are the settings OK? Do you have
opener or closer-contacts? 0V (NPN-Thyssen ) or+24V (z.B. Ziehl-Abegg,..)
-
Do have connected the brake wires correctly?
-
Do you have observed if the brakes open ? -> Brake wires ?
- Are the brake-contacts OK ? -> If you have any doubts, make a measurement !
F131
Monitor Brake-2:
-
Brake-circuit-2 does not open / closed during the travel -> Are the settings OK? Do you have
opener or closer-contacts? 0V (NPN-Thyssen ) or+24V (z.B. Ziehl-Abegg,..)
-
Do have connected the brake wires correctly?
-
Do you have observed if the brakes open ? -> Brake wires ?
Are the brake-contacts OK ? -> If you have any doubts, make a measurement !
F132
Monitor Brake-3:
-
Brake-circuit-3 does not open / closed during the travel -> Are the settings OK? Do you have
opener or closer-contacts? 0V (NPN-Thyssen ) or+24V (z.B. Ziehl-Abegg,..)
-
Do have connected the brake wires correctly?
-
Do you have observed if the brakes open ? -> Brake wires ?
- Are the brake-contacts OK ? -> If you have any doubts, make a measurement !
F133
Monitor Brake-4:
-
Brake-circuit-4 does not open / closed during the travel -> Are the settings OK? Do you have
opener or closer-contacts? 0V (NPN-Thyssen ) or+24V (z.B. Ziehl-Abegg,..)
-
Do have connected the brake wires correctly?
-
Do you have observed if the brakes open ? -> Brake wires ?
- Are the brake-contacts OK ? -> If you have any doubts, make a measurement !
F134
Monitor Main Contactor:
-
One of the main contactors cannot be switched ON -> Please control the contactors!
-
Please check the opener-contacts, clean it or change it!
- Are the opener-contacts for 24V DC ? -> Please look at the data sheet!
F135
ADC1-Zero-Offset:
- The current sensor-U is out of order. It is an internal error. Please contact our hotline.
F136
ADC2-Zero-Offset:
- The current sensor-V is out of order. It is an internal error. Please contact our hotline.
F137
ADC1-Offset:
- The AD-Changer-
V
is out of order. It is an internal error. Please contact our hotline.
F138
ADC2-Offset
:
- The AD-Changer-
U
is out of order. It is an internal error. Please contact our hotline.
F139
Ground Fault:
- The motor is out of order, please measure each coil of the motor and compare it!
- Please check, if the motorwire or resistor wire have any connection to the ground!
F140
IPM-Error: or Supply voltage to low:
-
Overtemperature in the IGBT-Chip
-> Is there any dirt on the pcb-board or in the heat sink ?
- The voltage of board is too low! -> Is the main supply voltage OK ?
F141
Position Regulation:
-
The difference at the start handling is too high, wrong parameter (
Nominal speed
-> motor-
datas,..)!
-
The motor works, but the encoder is out of order or falsely connected. -> Control the pinning!
-
Perhaps it is the wrong type of encoder? ->
Menu A4 Motor/Gearbox -> Encoder system
-
The number of pulses are wrong? ->
Menu A4 Motor/Gearbox -> Encoder Pulses
-
The encoder wire is out of order or too long ( >30m) ! -> Please increase the encoder voltage !
-
The encoder wire is parallel to the motor wire -> Change it immediately!
-
The encoder-shield is not connected to both sides -> Change it immediately!
Old machines: Please switch off the
position regulator
! Or change the settings!
F142
NTC-Dissipator ::
- The temperature sensor delievers the wrong value: Please check the connection!
- The temperature sensor is out of order. Please contact our hotline.
F143
DC Battery Voltage:
At the evacuation-travel with battery, the voltage of the battery was too low. Please check the battery
voltage!
F144
Watchdog-Reset
There is an internal reset by the watch dog. Please contact our hotline.
F145
Monitor Brake wear-1:
The input channel for the brake wear monitor is active. You need a new brake
shoe or brake is not correcty adjusted!
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...