KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 147 -
B608- ENERGY SAVING
PARAMETER: CAR LIGHT AUTOMATIC OFF
Car light can be off if car stands at rest in the stop place without calls or the car is in park stop.
This can be deactivated in the parameter
automatic off
.
PARAMETER: CARLIGHT DELAY
In order to avoid unnecessary in and turn-off processes of the car light one time interval should be
selected in the parameter which it can be proceeded that no more calls are present. One time interval
is adjustable from 0 to 6500 seconds. Default value is
60 seconds
.
PARAMETER: CAR INDICATOR AUTOMATIC OFF
Car indicater can be off if car stands at rest in the stop place without calls or the car is in park stop.
This can be deactivated in the parameter
automatic off
.
PARAMETER: CAR INDICATER DELAY
Time interval from 0 to 6500 seconds is adjusable. As default value is
120 seconds
selected.
PARAMETER: FLOOR INDICATER AUTOMATIC OFF
Floor indicater can be off if car stands at rest in the stop place without calls or the car is in park stop.
This can be deactivated in the parameter
automatic off
.
PARAMETER: FLOOR INDICATER DELAY
Time interval from 0 to 6500 seconds is adjusable. As default value is
300 seconds
selected.
PARAMETER: FREQUENCY INVERTER STANDBY
Frequency inverter can be in standby modus if the car stands inoperative in stop place.
The electronics boards are shifted into sleep modus and intermediate circuit are unloaded.
This can be activated in the parameter
Automatic off
.
PARAMETER: FREQUENCY INVERTER STANDBY DELAY
Time interval from 0 to 6500 seconds is adjusable. As default value is
600 seconds
selected.
PARAMETER: FREQUENCY INVERTER SWICH OFF
To the standby mode the frequency inverter becomes additionally completely without tension. The pro-
cedure is introduced over the elevator bus. This can be deactivated in the paramenter
automatic off
.
PARAMETER: FREQUENCY INVERTER SWITCH OFF DELAY
Time interval from 0 to 6500 seconds is adjustable. As default value is
900 seconds
selected.
PARAMETER: DOOR DRIVE TRAIN AUTOMATIC OFF
Door Drive Train can be off if car stands at rest in the stop place without calls or the car is in park stop.
This can be deactivated in the parameter
automatic off
.
PARAMETER: DOOR DRIVE TRAIN DELAY
Time interval from 0 to 6500 seconds is adjustable. As default value is
60 seconds
selected.
PARAMETER: MODUS S1
Operation mode S1( sleep mode ) is here activatable for the processor system.
PARAMETER: MODUS S2
Operation mode S2( deep sleep mode) is here activatable for the processor system.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...