B7 Input/ Output
General
In- and Output-channels at the control system DAVID-613 are easily programmable, i. e. the entrances
are exits of the computer units ZR, ZG , FKR , EIT and ITR can be occupied freely with the most different
in and base functions. In order to not occupy this control system with also over 350 input- and otput
functions each channel separately, preemption frameworks were introduces which make a preempition
possible of the channels. Nevertheless each free-programable entrance and exit with another function
can be occupied. In the menu B73 I/O preemption, preemption frameworks are to you at the disposal.
A fundamental proceed is to be planned as follows:
1. In menu
B73 I/O preemption
selects after the needs fitting preemption-frame.
2. Afterwards the entrances and exits are adapted after the control needs. This happens in the
menus B71 preemption Outputs and B72 preemption Inputs.
B71 Allocation Outputs
The outputs ZR-, ZG-, FKR-, and ITR-unit can be occupied in principle with the functions specified down.
No.
Display represenation
Function
A0
A00- no function
No function is assigned to the exit/relay.
A1
A01-Door movement
The relay tightens during a door movement.
A2
A02-Nudging
The relay tightens active function nudging with door latches.
A3
A03-EVACUATION
The relay energizes emergency power evacuation or fire drop evacuation.
A4
A04-CASE OF FIRE-EVACUATION The relay energizes the case of fire evacuation.
A5
A05-EMERGENCY POWER
The relay energizes the emergency power.
A6
A06-FIRE-BRIGADE PRIORITY
The relay energizes the fire- brigade priority.
A7
A07-CASE OF FIRE LEVEL
The relay energizes if the case of fire level is reached.
A8
A08-EMERGENCY POWER LEVEL The relay energizes if the emergency power level is reached.
A9
A09-FIRE-BRIGADE LEVEL
The relay energizes if the fire brigade level is reached.
A10
A10-DOOR FAULT
The relay falls if door fault is present.
A11
A11-OUT OF OPERATION
The relax falls if out of operation is present.
A12
A12-COLLECTIVE FAULT
The relay falls if motor temperature fault is present.
A13
A13-MOTOR TEMPERATURE
The relay falls if the motor temperature is present.
A14
A14-INSPECTION
Output if inspection service is on.
A15
A15-RESENT
Output if resent service is on.
A16
A16-NORMAL OPERATION
Output if normal operation service is on.
A17
A17-FULL LOAD
Output if full load is on.
A18
A18-OVERLOAD
Output if overload is on.
A19
A19-LESS LOAD
Output if less load is on.
A20
A20-PREFERENCE INSIDE
Output if preference inside is on.
A21
A21-PREFERENCE OUTSIDE
Output if preference outside is on.
A22
A22-PREFERENCE TOTAL
Output if preference total is on.
A23
A23-MOTOR FAN
Output at activated motor fan function.
A24
A24-CAR FAN
Output at activated car fan function.
A25
A25-CABINET FAN
Output at activated cabinet fan function.
A26
A26-ARROW UP
Arrow output upward.
A27
A27-ARROW DOWN
Arrow output downward.
A28
A28-HOLD INDICATOR
Output hold indicator.
A29
A29-ENTRY SIGNAL
Output entry signal ( Impuls 500ms).
A30
A30-LOCKED
Output locked.
A31
A31-DOOR CONTROL 1 OPEN
Output door control door 1 open.
A32
A32-DOOR CONTROL 1 CLOSE
Output door control door 1 close.
A33
A33-DOOR CONTROL 2 OPEN
Output door control door 2 open.
A34
A34-DOOR CONTROL 2 CLOSE
Output door control door 2 close.
A35
A35-SPECIAL TRIP
Output of the message special trip.
A36
A36-RESCUE TRIP
Output of the message rescue trip.
A37
A37-LEADER ENTERPRISE
Output of the message leader enterprise.
A38
A38-LOBBY MONITORING
The relay energizes with expiration of the adjusted time in the parameter B12.
A39
A39- Shaft door close
The relay energizes if at U 10 tension lies on. ( shaft door close)
A40
A40- Car door close
The relay energizes if at U 11 tension lies on. ( car door close)
A41
A41-out of operation invers
Output if the elevator is out of operation.
A42
A42-collective fault invers
Expenditure, if the plant shows a collecting fault signal.
A43
A43-releveling
Expenditure to control of the protection circuit.
A44
A44-parking level reach
Expenditure if the parking level is reached.
A45
A45 call messagering car fan
Expenditure call messaging at active car fan
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...