KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 82 -
B15- Mechanical Lock
PARAMETER: PULSE BUF. DELAY
With this parameter you can choose the delay-time of the lock-magnet in order to compensate contact
difficulties of the safety-contacts. The standard value is 500 ms.
PARAMETER: LOCK DELAY ON
This parameter allows a delay on the locked magnet. The standard value is without delay.
PARAMETER: LOCK DELAY OFF
With this parameter you can realize a delay-off-function of the lock-magnet. If you have horizontal car
doors, you need this function.
The standard value is without delay.
PARAMTER: LOCK HANDDOOR
If you have a handdoor and a horizontal car door, you must pay attention at this parameter.
You can
choose between the following values “Before the car door“ and “After the car door”. The standard value
is “After the car door“.
PARAMETER: OPEN AFTER LOCK
At the use of automatic shaft- and car doors with lock-magnet (electric sword), it is nessecary to switch
off the lock-magnet, before you try to open the car door. The delay-time for the car door is free program-
mable.
PARAMETER: MECHANICAL LOCK-OFF
This is the maximum time for activating the bold magnet without travel. The standard value is 30 sec-
onds.
PARAMETER: LOCK-SIGNAL
"Normal" or "Inverted" can be set. With "Normal" the lock is tightened while driving. The default value
is "Normal".
PARAMETER: Additional bolt delay
For cabin door locks you can program a delay here. This is required in conjunction with the control of
the car door. The factory setting has no delay. A possible average would be the setting of
1,0 seconds.
B16- Safety-Circuit
PARAMETER: PRE-OPENING DOORS
If the lift-controller has an integrated safety-circuit-pcb, yon can activate the function for drive into the
floor with open doors. During the drive into the floor, you need the message of the frequency inverter, if
the speed is below V < 0,3 m/s. Then the door can be opened.
PARAMETER: EARLY PREMAGN.
When this parameter is active and the frequency inverter in use support this function, the motor can be
set under voltage during the door-close-motion. After the safety circuit is closed, they can start without
time-delay. With this function the floor-delay-time can reduced very powerful. Activation and commis-
sioning of the function only after consultation with the technical hotline.
PARAMETER: EARLY PREMAGN.DELAY
You can choose a delaytime between 0.8 and 10 seconds. The standard value is 0.8 seconds.
PARAMTER: SAFETY CIRCIUTS
In this parameter you can choose the type of the safety-circuit-pcb. Ths standard value is the safety-
circuit-pcb SIS-16. For very old controller-systems, like DAVID-2001 you need the SIS-60 (Rekoba).
B17- Releveling
PARAMETER: RELEVELING
If the elevator controller has the option of a safety-circuit-pcb, you can switch on the function releveling
in the software.
Depending on the shaft-copy-system in use, you can make it in a digital system with the programming
unit HPG-60 in mm stepps, or you have a magnet-system, having to move the magnets.
PARAMETER: NO REVELING DISTANCE
This option is only necessary by a digital shaft copy system in use.
If you have a standard- or simple-
shaft-copy the length of the no releveling distance depends on the overcut of the
level-distance 12A and
12B.
The standard value for this parameter is 5 mm. The tolerance in the way is 2,5mm over and 2,5mm
under the level mark. The exacty value is depending of the art of ropes and the art of use of the elevator.
PARAMETER: MAX. RELEVELING DISTANCE
This option is only necessary by a digital shaft copy system in use.
If you have a standard- or simple-
shaft-copy the length of the releveling distance depends of the lenght of level-distance 12A or 12B.
The
length of the level-distance 12A and 12B must be shorter than the zone area.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...