3.8B OPTIONAL: Learning floors with the mehod„ With shaft table“
Assignment of the shaft table
In the menu item "Flush input", switch to the "Floor height" setting. Now you can enter the value in mil-
limeters for each floor, e.g. HS01-0000mm, HS02-3000mm.). After all floors have been preset, switch
back to the setting Flush Correction.
Performing the synchronization in the lowest floor
Now the ABS encoder must be synchronized with the controller, i. The control must assign the individ-
ual pulses to the reported impulse levels of the ABS encoder. To do this, drive the drive basket with
the manual control (return control or inspection control) to the lowest level flush and activate the Syn-
chronize HS01 menu item.
3.9 Setting the final delay V0 > 0
In the menu End delay V0> 0 learn to activate the point. The elevator drives about 0.5m with the
speed V0. After that, the delaying pain is learned and stored.
Note: Zones are not yet issued from SAFE copying, doors open at
standstill on the approached floor
3.10 Choice of travel speeds by adjusting the braking distances
If you only want to use speed V3 on your lift system, you can now give a couple of intercom
calls to check the entry behavior of the system.
However, if you also want to drive with the V1 or / and V2, or even have short-stay stops, you
must enter the delay paths for V1 or V2.
Please note when entering: braking
distance V1 <braking distance V2 <braking distance
V3
.By selecting the braking distance, you also specify the speed with which the elevator con-
trol approaches the stops. If a delay path for a speed has been set to the value zero, then
this speed is also no longer used by the controller.
Is e.g. if the two-storey floor space is smaller than the entered value "B43 Delay at V3", the
speed V2 is automatically selected during this drive (for example, floor drive for fast sys-
tems). If the floor distance is less than the entered value "B43 Delay at V2", the speed V1 is
automatically selected during this drive (for example, short landing stop).
If the floor distance is smaller than the entered value "B43 delay at V1", the speed V0 is au-
tomatically selected during this drive (extreme short stay, a few cm).
The parameter delay V3 must always have a value!
3.11 Measuring the irregularities and correcting the flush values
6.1
After checking from the controller that the elevator car does not override the stops and that
it is possible to drive from the cab, please bring your HPG60 and, if possible, connect it to
the FKR (car computer) on the car roof.
6.2
Take the elevator car to the first stop and select the Flush Level 1 parameter. Press the
yellow plus or minus buttons to set the hold inaccuracies.
->
If your elevator car is too high, press the minus button to enter the millimeter
value that your elevator car is too high.
->
If it is too low, pressing the plus button will enter the millimeter value that
your elevator car is too low. The calculated flush value is automatically cor-
rected.
6.3
Repeat the procedure for the other stops.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...