PARAMETER: DOOR MONITOR CLOSE
Within watch dog time the door must be closed. If this does not take place, then the door is reversed
and opened again. The procedure is repeated depending on the entered number of door attemps. The
universal time for the monitoring amounts to 13.0 seconds.
PARAMETER: FURTHER TRAVEL DELAY CAR CALL
If the elevator holds at the stop with car call and other severel calls are present, then this time starts
after opening the door. Passengers are also able to leave the cab in this time. Upon the expiration of
the driving on time inside, the door is closed and drives to the next stop. The standard value is 7,0 sec.
PARAMETER: FURTHER DELAY LANDING CALL
If the elevator holds at the stop with landing call and other severel calls are present, then this time starts
after opening the door. Passengers are also able to entry the cab in this time. Upon the expiration of the
driving on time outside, the door is closed and drives to the next stop. The standard value is 7,0 sec.
PARAMETER: FURTHER DELAY TIME TRIGGER
At expiration of the driving on time the door is closed. If the door is blocked, then it can be decided in
this parameter whether after the door reversion the driving on time is started again. The standard value
is NO.
PARAMETER: DOOR RESERVE DELAY
If the door is closing and it should be reversed, meaning it should be opened, then you need a delay
time to prevent a mechanical demage of the door. The standard value is 0,5 seconds.
PARAMETER: DOOR ENGINE 1/2/3 AT STANDBY OFF
In parameter you can select the time if the door engine does not work and the cab stands with closed
doors. You can use this preference if you choose the parameter„ Door engine“ and actively select the
attitude „always“. ( Parks-Standby-Ready)
PARAMETER:DOOR STANDBY MAIN
If there are no car- and landing-calls present in the elevator controller, then the lift is in the Stand-By for
future calls. In this condition you can choose for the door between open or close. The standard value is
open.
PARAMETER: DOOR ENGINE INSPECTION
In this parameter you can choose whether with manipulation of the inspection controller the door is
headed for. However you can operate the door controller over a separate control.
PARAMETER: DOOR OPEN
Selective together
Both buttons are parallel. If you push of a button ( Button1/ Button2), so opens the last running up to
door. When both doors are closed and you push the button ( Button1/ Button2) so opens only that door,
which are last closed.
Together
Both buttons are parallel. Both doors open by the pushing of the button ( Button1/ Button2)
Single
Button-1 opens Door-1, Button-2 opens Door-2
Selectively individually
Both buttons are running individually. If you push of a button ( Button1/ Button2) , so opens the last
running up to door. When both doors are closed and you push the button ( Button1/ Button2) so opens
only that door, which was last closed.
PARAMETER: BUTTON HOLDTIME
If a time is registered with this parameter, and the load time tracer operates, then the door can run not
for the adjusted time. During the load time if the load time tracer is pushed, then the load time is inter-
ruped and the door closes. The range of values for the load time extends between 1 and 600 seconds.
PARAMETER : HOLDTIME FUNCTION
In that parameter you can choose between ”single” and “ together”. Together means that a load time
tracer is responsible for both door sides. Single means that two load time tracers, which react separately
for the two door sides.
PARAMETER: BUTTON DOOR CLOSE FUNCTION
In that parameter you can choose between
single
,
together
and
selective
.
Together
means that the
Door-close-button, which is connected to Input of the EIT-device, is responsible for both door sides.
Single
mean that you need 2 Door-close-buttons, which react seperately for the two door sides.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...