KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 118 -
3.3 CANopen-Shaftcopysystem ANTS SAFE/ ELGO LIMAX 33CP
Parameter: Displacement measuring system
In this parameter, the used CANopen absolute value encoder system can be selected.
-
Variotech-ANTS SAFE
-
Kübler ANTS SAFE
-
LIMAX-33CP SAFE
Parameter: Status of the SAFE-copy
This parameter is only visible if a SAFE system has been selected. The display indicates whether the
selected SAFE system has been connected.
Parameter: Delay V0 => 0 – Fahrt AUF
The deceleration value is entered in mm. The factory setting is 100 mm.
Parameter: Delay V0 => 0 – Fahrt AB
The deceleration value is entered in mm. The factory setting is 100 mm.
Parameter: Delay bei V1 – Fahrt AUF & AB
The deceleration value is entered in mm. The factory setting is 500 mm.
Parameter: Delay bei V2 – Fahrt AUF & AB
The deceleration value is entered in mm. The factory setting is 1000 mm.
Parameter: Delay bei V3 – Fahrt AUF & AB
The deceleration value is entered in mm. The factory setting is 1500 mm.
PARAMETER: TRAVEL BY V0 – IF DISTANCE < xxxx mm
If the distance to the target floor is smaller than the specified distance xxxx mm, the speed V0 is selected,
regardless of the value set in the parameter Delay at V1.
PARAMETER: TRAVEL BY V1 – IF DISTANCE < xxxx mm
If the distance to the target floor is smaller than the specified distance xxxx mm, the speed V1 is selected,
regardless of the value set in the parameter Delay at V2.
PARAMETER: TRAVEL BY V2 – IF DISTANCE < xxxx mm
If the distance to the target floor is smaller than the specified distance xxxx mm, the speed V2 is selected,
regardless of the value set in the parameter Delay at V3.
Parameter: Forced delay Down auf V1
The deceleration value is entered in mm. The following settings are available:
- OFF, no forced delay
- Von 100 mm bis 15.000 mm
Parameter: Forced delay UP auf V1
The deceleration value is entered in mm. The following settings are available:
- OFF, no forced delay
- From 100 mm to 15.000 mm
Parameter: End delay V0 > 0
The following setting values are available: No or Yes.
When the parameters are activated, a short trip is triggered with an approximate length of 0.5m. The
final delay is determined and saved!
Parameter: Learn floor
In this parameter, it is possible to decide between two learning methods for determining the flush val-
ues. On the one hand, the "Manual approach" setting, in which each stop is approached with the in-
spection drive and when reaching the flushing value, this is stored. The other method "with shaft ta-
ble", the flush value is entered in millimeters for all floors and then synchronized in the lowest floor.
Parameter: Learning active (only with setting „Manual Start“)
The following settings are available:
- No -> No learning!
- Learn floor-01
- …
- Learn floor-n
Parameter: Flush positioning ( only with setting „Manual Start“)
In this parameter it is possible to decide between two input methods for the trimming table. On the one
hand, the setting "floor height", in which the value for each floor is entered in millimeters, and on the
other hand the setting "leveling correction", in which millimeter-like irregularities can be corrected.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...