KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 117 -
3.2 CANopen-Shaftcopysystems without SAFE
Parameter: displacement measuring system
In this parameter, the used CANopen absolute value encoder system can be selected.
-
Variotech-ANTS
-
Variotech-ANTS SAFE
-
LIMAX-33CP SAFE
-
Drehgeber
Parameter: shaft switch
This parameter is only visible if no SAFE system has been selected. The following settings are
available:
- No shaft switch
- Pre-end & zone switch
- Only zone switch
Parameter: shaft switch zones
This parameter is only visible if no SAFE system has been selected. The following settings are
available:
- zone 71 & 72 externally, i. via zone switch in the shaft
- zone-72 Simulation, i.e. Zone 71 via a zone switch in the shaft, zone 72 is generated via the
absolute value encoder system.
Parameter: short trips
This parameter is only visible if no SAFE system has been selected. The following settings are
available:
- No short stay
- 1 to 8 short stay stops
Parameter: Delay V0 => 0 – Drive UP
The deceleration value is entered in mm. The factory setting is 100 mm.
Parameter: Delay V0 => 0 – Drive Down
The deceleration value is entered in mm. The factory setting is 100 mm.
Parameter: Delay bei V1 – Drive UP & Down
The deceleration value is entered in mm. The factory setting is 500 mm
.
Parameter: Delay bei V2 – Drive UP & Down
The deceleration value is entered in mm. The factory setting is 1000 mm.
Parameter: Delay bei V3 – Drive UP & Down
The deceleration value is entered in mm. The factory setting is 1500 mm.
PARAMETER: TRAVEL BY V0 – IF DISTANCE < xxxx mm
If the distance to the target floor is smaller than the specified distance xxxx mm, the speed V0 is selected,
regardless of the value set in the parameter Delay at V1.
PARAMETER: TRAVEL BY V1 – IF DISTANCE < xxxx mm
If the distance to the target floor is smaller than the specified distance xxxx mm, the speed V1 is selected,
regardless of the value set in the parameter Delay at V2.
PARAMETER: TRAVEL BY V2 – IF DISTANCE < xxxx mm
If the distance to the target floor is smaller than the specified distance xxxx mm, the speed V2 is selected,
regardless of the value set in the parameter Delay at V3.
Parameter: Learning trip:
The following settings are available:
- Execute with V1 (factory setting)
- Execute with V2
- Execute with V3
Parameter: Forced delay Down auf V1
The deceleration value ist entered in mm. The following settings are available:
- OFF, no forced delay
- From 100 mm to 15.000 mm
Parameter: Forced delay UP auf V1
The deceleration value is entered in mm. The following settings are available:
- OFF, no forced delay
- From 100 mm to 15.000 mm
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...