KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 184 -
E464 E464 Attendant Mode OFF
If there is a pulse, then switch OFF
E465 E465 Attendant Mode UP
During the high signal, the door is closing and after that it starts up.
E466 E466 Attendant Mode DOWN
During the high signal, the door is closing and after that it starts down.
E467 E467 Attendant Mode Land.Con.Off
Toggle-Input for switching off the landing Control
E468 E468 Send Controler
When the input is high, then Send-Controlling
E469 E469 Reset all calls
When "1" then all adjacent calls cleared
E470 E470 Door Slice-OFF
When "1" then the door lock function is turned off, if active
E471 E471 Flash Output
Highsignal for the Blink Output
E472 E472 Release Door
E473 E473 Flap COP
E474 E474 Main Contactor No.
Additional contactor monitoring chain via normally open contacts
E475 E 475 Rope Stretching
By using the Weight Watcher Henning load-measure-systems the er-
ror rope stretching can be evaluated by the controller.
E476 E 476 Startdelay UP & Down
Function for the Acceleration
E477 E 477 Deadman Mode
If the input is active the controller is transferred to the dead man
mode.
E478 E478 Universal-input -5
Input for Universal-Output-5
E479 E479 Universal-input –6
Input for Universal-Output -6
E480 E480 Universal-input –7
Input for Universal-Output -7
E481 E481 Universal-input –8
Input for Universal-Output -8
E482 E482 Universal-input –9
Input for Universal-Output -9
E483 E483 Universal-input –10
Input for Universal-Output -10
E484 E484 Universal-input -11
Input for Universal-Output -11
E485 E485 Universal-input –12
Input for Universal-Output -12
E486 E486 Universal-input –13
Input for Universal-Output -13
E487 E487 Universal-input -14
Input for Universal-Output -14
E488 E488 Universal-input -15
Input for Universal-Output -15
E489 E489 Timer relay 1 Reset
Input for Reset the time relay 1
E490 E490 Timer relay 2 Reset
Input for Reset the time relay 2
E491 E491 Floorcalls OFF
Landing calls are not accepted
E492 E492 Temerature Heat Travel
Thermostat input for the heating function
E493 E493 UCM Status 1
Input channel for the EN81-A3 Function for UCM-Status 1
E494 E494 UCM Status 2
Input channel for the EN81-A3 Function for UCM-Status 2
E495 E495 UCM Status 3
Input channel for the EN81-A3 Function for UCM-Status 3
E496 E496 TV60-1
Synchronous monitoring channel 1 of the TV60-1
E497 E497 TV60-2
Synchronous monitoring channel 2 of the TV60-1
E498 E498 OSKAR Release
FRAPORT – Safety system OSKAR
E499 E498 OSKAR Wait
FRAPORT – Safety system OSKAR
E500 E500 OSKAR Block
FRAPORT – Safety system OSKAR
E501 E501 OSKAR OFF
FRAPORT – Safety system OSKAR
E502 E502 Parking Fill
When the level is „1“ then the fill-operation is active.
E503 E503 Parking Empty
When the level is „1“ then the empty-operation is active.
E504 E504 TV60-3
Synchronous monitoring channel 1 of the TV60-2
E505 E505 TV60-4
Synchronous monitoring channel 2 of the TV60-2
E506 E506 RESET Brake monitoring
Possibility of external reset during braking control elements and A3
case.
E507 E507 Battery monitoring 1
Monitoring of the battery of EOS or other units
E508 E508 Battery monitoring 2
Monitoring of the battery of EOS or other units
E509 E509 Rubber Skirt
Function for Monitoring the rubber skirt
E510 E510 Fire Sensor Floor 01 Door 2
Input for Fire Evaquation - Fire Sensor Floor 01 Door 2
E511 E511 Fire Sensor Floor 02 Door 2
Input for Fire Evaquation - Fire Sensor Floor 02 Door 2
E512 E512 Fire Sensor Floor 03 Door 2
Input for Fire Evaquation - Fire Sensor Floor 03 Door 2
E513 E513 Fire Sensor Floor 04 Door 2
Input for Fire Evaquation - Fire Sensor Floor 04 Door 2
E514 E514 Fire Sensor Floor 05 Door 2
Input for Fire Evaquation - Fire Sensor Floor 05 Door 2
E515 E515 Fire Sensor Floor 06 Door 2
Input for Fire Evaquation - Fire Sensor Floor 06 Door 2
E516 E516 Fire Sensor Floor 07 Door 2
Input for Fire Evaquation - Fire Sensor Floor 07 Door 2
E517 E517 Fire Sensor Floor 08 Door 2
Input for Fire Evaquation - Fire Sensor Floor 08 Door 2
E518 E518 Door 1 Manual Opening
Input channel for Door 1 Manual Opening
E519 E519 Door 1 Manual Closing
Input channel for Door 1 Manual Closing
E520 E520 Door 2 Manual Opening
Input channel for Door 2 Manual Opening
E521 E521 Door 2 Manual Closing
Input channel for Door 2 Manual Closing
E522 E522 Hazardous Transport Off
Input function to switch off the Hazardous Transport
E523 E523 Reset Door is Ready
Input channel for Reset function Door is Ready
E524 E524 Quickstart Monitor
Input channel for monitoring the relay function of K69
E525 E525 Car Light Sensor
Input channel for the car light sensor to monitor the car light
E526 E526 Car Preference Call Pulse
E527 E527 Car Preference Call Release
E528 E528 Inspection E-A 68
Inspection ON / OFF in the pit, „0“=ON / „1“ = OFF
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...