KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 249 -
3.9B OPTIONAL: Floors learn with the method „With shaft table“
Assignment of the flush positioning
In the menu item "Flush input", switch to the "
Floor height
" setting. Now you can enter the value in
millimeters for each floor, e.g. HS01-0000mm, HS02-3000mm.). After all floors have been preset,
switch back to the setting Flush Correction.
Performing the synchronization in the lowest stop
Now the ABS encoder must be synchronized with the controller, i. the controller must assign the indi-
vidual pulses to the reported impulse levels of the ABS encoder. To do this, drive the drive basket with
the manual control (return control or inspection control) to the lowest level flush and activate the Syn-
chronize HS01 menu item.
3.10 Setting the Final deceleration V0 > 0
In the menu
Final deceleration V0>0
learn to activate the point
. The elevator moves about 0.5m at
the speed V0. After that, the delaying pain is learned and stored.
Note: There are still no zones issued by the SAFE copy, doors
open at standstill in the approached floor
3.11 Choice of travel speeds by adjusting the braking distances
If you only want to use the V3 speed on your lift system, you can now give a couple of intercom calls to
check the entry behavior of the system.
However, if you also want to drive with the V1 or / and V2, or even have short-stay stops, you must enter
the delay paths for V1 or V2.
Please note when entering: braking distance V1 <braking distance V2 <braking distance V3
By choosing the braking distance, you also specify the speed with which the elevator control approaches
the stops. If a delay path for a speed has been set to the value zero, then this speed is also no longer
used by the controller.
Is e.g. If the floor level of two floors is smaller than the entered value "B43 Delay at V3", then the
speed V2 is automatically selected during this drive (for example floor drive for fast systems). If the
floor distance is less than the entered value "B43 Delay at V2", the speed V1 is automatically selected
during this drive (for example, short landing stop).
If the floor distance is smaller than the entered value "B43 delay at V1", the speed V0 is automatically
selected during this drive (extreme short stay, a few cm).
The parameter delay V3 must always have a value!
3.12 Measuring the irregularities and correction der Bündigwerte
1
After checking from the controller that the car does not override the stops and that it is
possible to drive from the cab, please bring your HPG60 and, if possible, connect it to the
FKR (car computer) on the car roof
2
Take the car to the first stop and select the parameter Flush Level 1. Press the yellow plus
or minus buttons to seat the stop inaccuracies.
->
If your elvator car is too high, press the minus button to enter the millimeter
value that your elevator car is too high.
->
If it is too low, pressing the plus button will enter the millimeter value that
your elevator car is too low. The calculated flush value is automatically cor-
rected.
3
Repeat the procedure for the other stops.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...