4.3 ELGO LIMAX CP33 – Brief summary of commissioning
Status LIMAX33CP: Setup-1-Konfig. (only possible if LIMAX33CP still without basic
configuration)
Possible settings:
1. LIMAX33 Exit: eSGC Elevator arrestor activ:
no
2. LIMAX33 Inspection:
Monitoring
/No cabling
3. LIMAX33 Nominal speed: 1,000m/s
4. LIMAX33 Delay control ETSL: off / on
If delay control=yes:
a. LIMAX33 ETSL Delay brake: 01,400m/s²
b. LIMAX ETSL Delay: 100ms
c. LIMAX33 ETSL Buffer speed: 0,600m/s
d. LIMAX33 ETSL Offset up: 0010mm
e. LIMAX33 ETSL Offset down: 0010mm
5. LIMAX33 Configuration to save: no/yes
Status LIMAX33CP: Setup-2
Possible settings:
1. LIMAX33 Zone: Length= +-200mm
2. (if in setup-1 „Inspection: Monitoring“ activated) LIMAX33 Inspection: none
3. End switch/End switch up/End switch down/End switch up+down
4. LIMAX33 End switch UP learn: no/yes
5. LIMAX33 End switch DOWN learn: no/yes
Status LIMAX33CP: Setup-3
Status LIMAX33CP: Setup-3
Possible settings:
1. LIMAX33 Etagen: Learning trip start: no/yes
2. LIMAX33 End switch UP learn: no
3. LIMAX33 End switch DOWN learn: no
Status LIMAX33CP: Normal Operation
Possible settings: (Insp/Return motion must be activated)
1. LIMAX33 Zone: can be changed in the range +-10 bis +-200mm.
2. LIMAX33 Inspection (If Inspection monitoring activ): Inspection limit switches can
be activated or deactivated.
3. LIMAX33 End switch UP push: Can be moved in the range 0 bis -980mm com-
pared to the learned limit switch point UP.
4. LIMAX33 End switch DOWN push: can be moved in the range 0 to + 980mm op-
posite to the learned limit switch point DOWN.
5. LIMAX33 Learn new floors: no/yes: A new floor learning drive for the safe copy
can be carried out (Insp/Return motion must be disabled).
6. LIMAX33 End switch UP learn: The limit switch Point UP can be taught-in again.
To do this, the cab must be moved manually to the desired limit switch position,
then confirm with YES. New limit switch position must be above the lower limit
switch position.
7.
LIMAX33 End switch DOWN learn: The limit switch point DOWN can be taught in
again. To do this, the cabin must be moved manually to the desired limit switch
position below, then confirm with YES. New limit switch position must be below
the upper limit switch position.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...