The output of the car controller conditions effected with group plants codes. An output in “the 1 of N”-
format is not possible, but the Binary code and Gray code are available. The output for arrow is se-
lectable between far trip and direction of travel arrows. The output for gong separately takes place for
both plants. At the exits 330 & 331 as well as 332 & 333 only one miniature speaker is attached. Volume
and pitch, as well as multiple gong are adjusted over the control.
Each remote station needs its own address in the system. This address is modulated with the ER-2005
over DIP switch on the PCB.
Address input remote station 1. group-bus ( for 2 elevators)
Floor
Number / Setup at the Dipp-switch
Floor
Number / Setup at the Dipp-switch
1
000000
9
001000
2
000001
10
001001
3
000010
11
001010
4
000011
12
001011
5
000100
13
001100
6
000101
14
001101
7
000110
15
001110
8
000111
16
001111
Address input remote station 2. group-bus ( for 2 elevators)
Floor
Number / Setup at the dipp-switch
Floor
Number / Setup at the dipp-switch
1
010000
9
011000
2
010001
10
011001
3
010010
11
011010
4
010011
12
011011
5
010100
13
011100
6
010101
14
011101
7
010110
15
011110
8
010111
16
011111
If you have an elevator group between 17 and 32 floors, you need a second group bus with the follow-
ing address:
Floor
Number / Setup at the dipp-switch
Floor
Number / Setup at the dipp-switch
1
010000
32
011111
Parameter:
Group Dynamic – Travel Time Floor
In this parameter, the average travel time is specified between two floors.
Together with the holding time can be the approximate travel time for an elevator installation with the
present calls extrapolate.
Parameter:
Group Dynamic – Stop Time Floor
In this parameter, the average hold time is specified in the floor.
Along with the travel time can be the approximate travel time for an elevator installation with the pre-
sent calls extrapolate.
Parameter:
Group Dynamic – Call Sharing
Setting the call distribution: "dynamic" or "energy-saving"
Dynamically when hiring a standing lift is preferred for call distribution. If the setting has been selected
energy saving, tries to distribute the call to an appropriate moving elevator.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...