KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 42 -
FUNCTION-VISUALISATION
When the ER-2013/2014 connected with bus line and the control is
active, the green LED is blinking. In short circuit on the busline or mal-
function expires or shine the LED. You can control the Remote Station
in Menu C6 Modul Monitor/ Remote Station ER01-16 and Remote
Station ER 17-32.
For every remote station which function is ok, there will be shown an
„
E
“ in the display of the HPG-60. From left to right, you can see in
the display all remote stations from the first floor to the highest floor
which are recognized in the system.
ADRESS SETTING
All ER-2014 preset for the individual floors. The bottom floor has al-
ways marked “Floor 01”. The setting of floors is no longer adress
switch on the Remote Station, like ER-2005, but by setting software.
1. STEP:
Switch off the controller (
Main Switch Q1, and Fuses
F6 & F7 switch off
).
2. STEP:
The Remote Station programmed with the RJ-45 cable
with the central unit. All other Remote Stations may not be connected.
3. STEP:
It must be set a jumper on the 5-pin socket Print be-
tween pins 2 and 3 (-> see picture left). Then, the system can be put
under power (main switch Q1, Q6 is switched on).
4. STEPt:
You can regulate the parameter “Remote Station Adress
programming” in menu C6 Modul Monitor. The ER-2014 gets his
adress with the selection of the number of floors. (01-64). Then the
ER-2014 can be installed in the corresponding floor.
TERMINAL: MATRIX-INDICATOR TYPE ANZ-xx
The connection of the Matrix-indicator of type ANZ-XX (ANZ-22,
ANZ-32, ANZ.-33, ANZ-52 & ANZ-53) takes place on the black RJ-
12 jack with the black RJ-12 cable.
Don’t put the RJ-12 in the silber RJ-45 jack!
Connection of a TFT-Displays at a ER-
2014
The connection of TFT displays is done by the yel-
low RJ-12 jack with the included RJ-12 cable.
The RJ-12 cable
is not allowed to be plugged
into
the RJ-45 jack silver or in one of the two RJ12 sock-
ets for matrix display!
Connection of several TFT-Displays at
an ER-2014
Several TFT displays can be operated at a terminal
by means of a RJ-12 splitter.
This is necessary in elevator installations with sev-
eral door sides, or in elevator groups.
On the remote station ER-2014 is a 2-pole DIL switch for activating functions.
1. Switch-1 can be used to switch on termination. The termination is only to be activated for
the last floor computer on the bus.
2.The passive bus is activated on switch-2. A passive bus can only output information, e.g.
Arrows and cabin stand. It therefore operates in the same address space as the Shaftbus-1.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...