KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 73 -
A-LIFTPARAMETER
A1- LIFT TYPE
PARAMETER: A1.1 TYPE
There is a place of 20 characters to put in the name of the type or the company. The whole character-
set is 95 characters.
PARAMETER: A1.2 LIFT NUMBER
There is a place of 20 characters to put in the lift number. The whole character-set is 95 characters.
PARAMETER: A1.3 CONTROLLER NUMBER
There is a place of 20 characters to put in the controller-number. The whole character-set is 95 char-
acters.
PARAMETER: A1.4 PLACE
There is a place of 20 characters to put in the name of the place. The whole character-set is 95 charac-
ters.
PARAMETER: A1.5 TIME/DATE
You must use the form
xx:xx:xx = time & yy.yy.yyyy = Date
to put in the time and the date.
PARAMETER: A1.5a Summer/Wintertimeswitching
You can make a automaticly or manual switching.
PARAMETER: A1.6 LANGUAGE
There are two languages, which you can choose
German and
English
. The standart is German.
PARAMETER: A1.7 & A1.8 - DISPLAYLINE 1 AND 2
There is a place of 20 characters in every line to put in the name of the building, or the company. These
two lines are visible at the start on the HPG-60. The whole character-set is 95 characters.
PARAMETER: A1.9 SOFTWARE VERSION
In this menu the software version will be shown.
-
DAVID-613 ZR – 00.076 or higher
-
DAVID-613 PIC – 00.025 or higher
-
DAVID-613 FKR – 00.013 or higher
-
Maintenance-LCD – 00.01 or higher
-
ER-Bus-1 to ER-Bus-3 All ER-Shaft bus calculator
-
Expansionbus ZG32 / Sensormodule / Shaft pit calculator
-
Expansiongroup ZG16
-
Relay group RG12
PARAMETER: A1.10 CODEWORD INPUT
If the Code-word is >< 0000, then it is active, e.g. after switch off the D613 ZR or put off the HPG-60.
If the parameter code-word is active, you must put in the right code-word, before you can change the
others parameters.
In four waye, the code-word protection is active:
- Unit is switched off
- At 00:00 clock
- A wrong code-word is put in
- A new code-word is put in
The following unit are without code-word protection:
- To give car calls
- To give landig calls
- Error memory
A2- Controller
PARAMETER: A2.1 TYPE OF DRIVE
In this parameter, you have to choose the type of drive:
-
Scanclimber- Variable Frequency
-
Rope- Variable Frequency
-
Rope- Variable Voltage
-
Rope- 2 Speeds
-
Hydraulic-Variable Frequency
-
Hydraulic- regulated
-
Hydraulic-Not regulated
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...