The standard value for this parameter is 100mm. This is the releveing-way for one direction.
Please look at the lenght of the door-sword!
PARAMETER: LEVELING UP/DOWN
This option is only possible by a digital shaft copy system in use.
PARAMETER: TIME LIMIT
The parameter of the time limit is crucial for a retrieving procedure. The standard value is 20 sec. In this
time interval if the retrieving procedure is not successfully brought to end, then it is broken.
PARAMETER: NUMBER OF ATTEMPS
With this parameter the number of attemps can be limited with the regulation, in order to e.g. protect the
hydraulic aggregate against overheating. The standard value is 20 efforts.
PARAMETER: LIMIT AT LEVEL 1
When car is in bottom level, you can choose in this parameter if the number of the releveling-attemps
should be reduced, like in the parameter before or with no limit.
PARAMETER: OVERLOAD
With this parameter you can choose, if the releveing-function is active when the overload procedure is
present. The standart value is the active releveling, according to the EN81.
PARAMETER: FAULT HANDLING
If there is an error at the releveling-function, the following reactions are possible:
-
“
Lowering & Block
”- This value can be used for hydraulic elevators. The car is lowered into the
lowest stop place, in order to avoid an uncontrolled lowering.
-
„
Block Immediately
“ – This value can be used for rope elevators.
-
„
Next Floor &
Block
“ – This value can be used for rope elevators.
-
Only
“Fault Entry”
– no blocking.
PARAMETER: FINE –RELEVELING
The releveling will be handled by an external hydraulic-aggregate. Made the following settings:
1) ALGI - fine releveling
2) BUCHER - fine releveling
PARAMETER: PIEZO-ALERT AT UNLEVELING
If the car is not flush in the range of more than 20mm and smaller than 500mm and this parameter is
activated, the piezo alarm rings. The standard setting is
YES
.
B2 Call Options
B21 Car Calls
PARAMETER: DOOR REVERSE CAR CALL
With activation of this function, the closing of the door will be reversed if the control button in the car is
pushed at the current landing, i.e. the door stops and reopens.
PARAMETER: SELECTIV CAR CALLS
In this parameter the selective door control activates with a second car call strand. At the floor with front
and back door in each case 2 call buttons are present. Button 1/ 2 opens Door1/ 2.
PARAMETER: SELECTIV CAR CALLS
In this parameter you choose the time after which the car calls are deleted, if an error happens. The
standard value is 4,0 sec.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...