KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 119 -
Parameter: Synchronize HS01 (only with settings “With shaft table“)
After the route has been detected, the car in the bottom floor is flushed and this parameter is activated.
As a result, the controller recognizes the flush value of the lowest station.
Parameter: Leveling by Car-Panel
The level adjustment via the cabin interior panel is possible with digital copying with an incremental
encoder or with an absolute encoder. The prerequisite is that the floors have been taught in, the elevator
drives to all floors via inside / outside calls and always stops in the same position on the respective floor.
B43 Leveling by Car-Panel
B43 Leveling by
car-panel: yes
Carpriority aktive
Esc Enter Wert
Activate the parameter in menu B42 / 43: "Flush correction for cab-
ine panel: yes"
Now the elevator is in the special mode "Interior preferential", the
car door remains open on the floor, the landing calls are deac-
tivated, display "SPECIAL TRAVEL". Calls can now only be trig-
gered via the interior panel.
In order to activate the flush adjustment with the help of the interior panel, the cabin
must be within the zone area.
Now hold down the
"DOOR OPEN" button
for three seconds. There is a double
acoustic acknowledgment. The two call buttons "lowest floor" and "lowest floor + 1"
now flash.
The display of the TFT / LED matrix switches to the adjustment mode. Car calls can
no longer be triggered now; the flashing call buttons are used to enter the level.
With the
“lowest floor” call button
, the
level
downwards
can now be corrected if the cabin is
too high. With the
call button "lowest floor + 1"
,
the level can be
corrected upwards
if the car is
too low.
Each press of the button changes the correction
value by 1mm up or down and is acknowledged
with an acoustic signal. If the corresponding call
button is held down for more than 2 seconds, the
correction value is changed by 10mm. This is
acknowledged with an acoustic double signal. The
currently selected value of the flush adjustment ap-
pears in the display.
To save the corrected leveling value, the "DOOR OPEN" button must be pressed
for two seconds. The entry is acknowledged with a longer acoustic signal. The value
is now saved, the two lowest indoor call buttons no longer flash, the display changes
back to the normal display mode. Now another level can be approached with the
help of the car call button and the leveling correction can be made there.
The control is still in the special mode "Internal priority". After the flush has been
adjusted on all floors, the control must be switched back to normal mode. This hap-
pens either by deactivating the parameter in menu B42 / 43: "Flush correction car
panel: no" or by briefly activating the inspection mode. After one hour, the parameter
is automatically deactivated by the control.
Parameter: Flush-Level-XX
After a successful learning run or entry of the stands in the menu item flush input, the flattening levels
are stored in millimeters for the individual levels in this parameter. Unboundedness can be corrected
in millimeters with minus and plus on the HPG-60. If the value floor height has been selected in the
flush input menu, the value in millimeters can be entered for each floor (for example HS01-0000mm,
HS02-3000mm).
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...