PARAMETER: Inspection Call
This parameter is activated by entering a lowering value of the cabin. The procedure for retrieving the
cabin for inspection is as follows:
1.) Lift the elevator cabin by call.
2.) In the cabin, the DOOR-UP button, the INTERIOR button on the current floor, and the INTERIOR
buttons on the floor below are simultaneously pressed for 2 seconds until a piezoton sounds for the
active quotation.
3.) Now the cabin has to be left. After completion of the piezotone, the lift control closes the cabin &
shaft doors and lowers the cabin.
4.) After completion of the lowering process, the piezotone rings again for 30 seconds and the opera-
tor has the possibility to unlock the door and initiate the inspection drive.
5.) If the 30-second duration is not used, or if a passenger is placed in the cab using an indoor com-
mand, the cabin flushes again, opens the door and goes into normal operation.
PARAMETER: Monitoring Manual Speed according EN81-20/50
According to EN81-20 / 50 the return speed of max. 0.63 m / s to 0.3 m / s and must not be exceeded.
By setting the monitoring threshold to 0.3 m / s on the factory side, travel is interrupted if the distance
is exceeded, but no blocking occurs. The error message F253 "Over speed return travel" appears.
Prerequisite is the correct entry of the nominal speed of the elevator system in parameter A3.6.
The factory setting must be adapted before LOCATION!
PARAMETER: Monitoring Inspection Speed according EN81-20/50
According to EN81-20 / 50 the inspection speed must be monitored. Normal inspection speed is set to
0.3 m / s. The inspection speed can be increased to 0.5 m / s by pressing the rapid button on the in-
spection bobbin. In this way the factory setting of the monitoring threshold must be corrected on site. If
the threshold is exceeded, the trip is interrupted, but no blocking occurs. The error message F254
"Over-speed inspection travel" appears.
Prerequisite is the correct entry of the nominal speed of the elevator system in parameter A3.6.
The factory setting must be adapted in the elevator!
Parameter: pit module ERG
If a pit module, e.g. an ERG-2018 exists, this parameter must be activated. If the pit module fails, the
inspection mode is automatically activated.
B602- EMERGENCY LIGHT SYSTEM
General
The emergency power equipment is integrated in that central unit controller makes with 12V a maximum
river available of 1,2A. This power serves 1.1 AH Batteries, as well as for the supply of the intercom, for
the supply of the 12V the alert tracer, the alert horn, the concise announcement and the emergency
light.
PARAMETER: ALERT PUSH BUTTON DELAY
The alarm tracer activation can be retarded in the menu option delay alarm from one to five seconds,
so that abuse and erroneous manipulation can be mostly prevented. If an error enters the lift, then the
alarm delay becomes ineffective, and the notification of emergency imparted.
PARAMETER: ALERT PUSH BUTTON MISUSE PROTECTION
If
Off
: Alarm is released after deceleration time
If
On
: Alarm is not released under the following conditions:
- Elevator is located concisely in floor
- Door is open
- Elevator stands on “ normal operation” ( no inspection/ resend drive enterprise)
- There is no error
If one of these conditions is not full filled, the alarm is released.
Содержание DAVID 613
Страница 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Страница 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Страница 7: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 7 8 INDEX 263...
Страница 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Страница 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Страница 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Страница 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Страница 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Страница 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Страница 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...
Страница 124: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 124 Unit shaft copying system...