GE Multilin
C70 Capacitor Bank Protection and Control System
B-47
APPENDIX B
B.4 MEMORY MAPPING
B
B60B
...Repeated for Module 2
B676
...Repeated for Module 3
B6E1
...Repeated for Module 4
B74C
...Repeated for Module 5
B7B7
...Repeated for Module 6
B822
...Repeated for Module 7
B88D
...Repeated for Module 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (8 modules)
B900
Configurable GOOSE Dataset Items for Transmission
0 to 128
---
1
F233
0 (None)
B940
...Repeated for Module 2
B980
...Repeated for Module 3
B9C0
...Repeated for Module 4
BA00
...Repeated for Module 5
BA40
...Repeated for Module 6
BA80
...Repeated for Module 7
BAC0
...Repeated for Module 8
Contact Inputs (Read/Write Setting) (96 modules)
BB00
Contact Input 1 Name
---
---
---
F205
“Cont Ip 1“
BB06
Contact Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
BB07
Contact Input 1 Debounce Time
0 to 16
ms
0.5
F001
20
BB08
...Repeated for Contact Input 2
BB10
...Repeated for Contact Input 3
BB18
...Repeated for Contact Input 4
BB20
...Repeated for Contact Input 5
BB28
...Repeated for Contact Input 6
BB30
...Repeated for Contact Input 7
BB38
...Repeated for Contact Input 8
BB40
...Repeated for Contact Input 9
BB48
...Repeated for Contact Input 10
BB50
...Repeated for Contact Input 11
BB58
...Repeated for Contact Input 12
BB60
...Repeated for Contact Input 13
BB68
...Repeated for Contact Input 14
BB70
...Repeated for Contact Input 15
BB78
...Repeated for Contact Input 16
BB80
...Repeated for Contact Input 17
BB88
...Repeated for Contact Input 18
BB90
...Repeated for Contact Input 19
BB98
...Repeated for Contact Input 20
BBA0
...Repeated for Contact Input 21
BBA8
...Repeated for Contact Input 22
BBB0
...Repeated for Contact Input 23
BBB8
...Repeated for Contact Input 24
BBC0
...Repeated for Contact Input 25
BBC8
...Repeated for Contact Input 26
BBD0
...Repeated for Contact Input 27
BBD8
...Repeated for Contact Input 28
BBE0
...Repeated for Contact Input 29
BBE8
...Repeated for Contact Input 30
BBF0
...Repeated for Contact Input 31
BBF8
...Repeated for Contact Input 32
BC00
...Repeated for Contact Input 33
BC08
...Repeated for Contact Input 34
BC10
...Repeated for Contact Input 35
Table B–9: MODBUS MEMORY MAP (Sheet 40 of 53)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание UR Series C70
Страница 2: ......
Страница 10: ...x C70 Capacitor Bank Protection and Control System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 C70 Capacitor Bank Protection and Control System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 124: ...4 30 C70 Capacitor Bank Protection and Control System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 344: ...5 220 C70 Capacitor Bank Protection and Control System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 396: ...8 18 C70 Capacitor Bank Protection and Control System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 414: ...9 18 C70 Capacitor Bank Protection and Control System GE Multilin 9 1 OVERVIEW 9 THEORY OF OPERATION 9 ...
Страница 436: ...10 22 C70 Capacitor Bank Protection and Control System GE Multilin 10 4 SETTING EXAMPLE 10 APPLICATION OF SETTINGS 10 ...
Страница 547: ...GE Multilin C70 Capacitor Bank Protection and Control System B 79 APPENDIX B B 4 MEMORY MAPPING B ...
Страница 548: ...B 80 C70 Capacitor Bank Protection and Control System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Страница 586: ...D 10 C70 Capacitor Bank Protection and Control System GE Multilin D 1 OVERVIEW APPENDIXD D ...
Страница 598: ...E 12 C70 Capacitor Bank Protection and Control System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...